Signals emitted by LED B of the receiver
Long flashes > GREEN
On start-up:
1 Z = Current encoding system: "Flo"
2 Z = Current encoding system: "O-Code" / "O-Code/A" / "FloR" / "FloR/A"
3 Z = Current encoding system: "Smilo"
5 Z = No remote control memorised
During operation:
1 Z = Indicates that the code received is not stored in the memory
3 Z = Saving code in memory
5 Z = Memory deleted
6 Z = During programming, indicates that the code is not authorised for memorisation
8 Z = During programming, indicates that the memory is full
Short flashes > GREEN
1 Z = "Certificate" not valid for memorisation
2 Z = During programming, indicates that the code cannot be memorised because it transmits the "cer-
tificate"
4 Z = Output in "Mode 2" not managed on control unit
17 - English