6.4
Installation
Installation and operating instructions Wilo-EMU TR/TRE 212 ... 326-3
Installation and electrical connection
DANGER
Danger due to fluids hazardous to health during installation!
Ensure that the installation site is clean and disinfected during installation. If contact
with fluids that are hazardous to health is possible, observe the following points:
• Wear protective equipment:
⇒ Closed safety goggles
⇒ Face mask
⇒ Protective gloves
• Wipe up drips immediately.
• Observe information from the work regulations! The operator must ensure that the
personnel have received and read the work regulations!
DANGER
Risk of fatal injury due to dangerous lone working practices!
Working in pump chambers and tight spaces as well as working where there is a danger
of falling is dangerous work. This work must not be carried out alone! A second person
must be present for safety reasons.
WARNING
A lack of protective equipment may result in hand and foot injuries or risk of
falling!
During work there is a risk of (serious) injury. Wear the following protective equipment:
• Safety gloves that protect against cuts
• Safety shoes
• Safety harness
• If lifting equipment is used, a protective helmet must also be worn!
CAUTION
Material damage due to incorrect fixation
Incorrect fixation may limit the functionality of the mixer or damage it.
• If the mixer is fixed to a concrete structure, use anchor bolts for fixation. Follow the
manufacturer's installation instructions! Temperature specifications and hardening pe-
riods must be strictly observed.
• If the mixer is fixed to a steel structure, ensure that the structure is sufficiently strong.
Use fixation materials with sufficient strength!
Use suitable materials to avoid electrochemical corrosion!
• Tighten all screwed connections. Observe torque specifications.
en-US