Operating Modes; Operation With Frequency Converter; Operation In An Explosive Atmosphere - Wilo EMU TR 212 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en-US
4.3

Operating modes

4.4
Operation with frequency con-
verter
4.5
Operation in an explosive atmos-
phere
Approval according to
ATEX
FM
CSA-Ex
14
Product description
Legend
− = not available/possible, o = optional, • = standard
* In the Ex version, this monitoring is omitted and not substituted!
** A temperature limiter is in-built as standard. The Ex version as per ATEX also features an
installed temperature controller and limiter.
All monitoring devices fitted must be connected at all times!
Monitoring the motor compartment and sealing chamber
The motor compartment monitoring protects the motor winding from short-circuits. The
sealing chamber control detects fluid ingress from the gear chamber. In each case, the hu-
midity is recorded by an electrode in the motor compartment and sealing chamber.
NOTICE! In the Ex version, this monitoring is omitted!
Motor winding monitoring
Thermal motor monitoring protects the motor winding from overheating. A temperature
limiter with a bimetallic strip is fitted as standard. Once the activation temperature has been
reached, deactivation with reactivation lock must take place.
As an option, the temperature can also be measured with a PTC sensor. Thermal motor
monitoring can also be designed as a temperature controller. This allows two temperatures
to be measured. Once the low activation temperature has been reached, an automatic reac-
tivation can be initiated after the motor has cooled down. The unit is forced to deactivate
with reactivation lock once the high activation temperature has been reached.
External monitoring of the pre-chamber
The pre-chamber can be equipped with an external pencil electrode. The electrode registers
fluid ingress through the mechanical seal on the fluid side. An alarm or deactivation of the
mixer can therefore be activated via the system controller.
Operating mode S1: Continuous duty
The mixer can operate continuously at the rated load without exceeding the permissible
temperature.
Operation on the frequency converter is permitted. Refer to the appendix for the relevant
requirements!
o
o
o
o
o
o
o
o
o
o
o
Legend
− = not available/possible, o = optional, • = standard
For use in explosive atmospheres, the mixer must be marked as follows on the rating plate:
ƒ
"Ex" symbol for the relevant approval
ƒ
Ex classification
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
WILO SE 2021-05