• Once the pH probe is bathing in pH 7 solution, press
• The screen will next display pH calibration in progress (refer Figure 6.12). A count will commence.
Typically, the calibration will take less than 15 seconds, but may take up to a minute;
Figure 6.12
• Once complete, the display will instruct you to remove the probe (refer Figure 6.13).
Figure 6.13
• The probe can then be removed from the pH calibration solution and installed into the probe and
injection housing. The injection housing has written in the moulding which probe is mounted where
(refer Figure 6.14);
Figure 6.11
menu/setting select;
ph calibration:
in progress . . .
58
ph calibration:
complete
remove probe
21