Abicor Binzel iCAT Instructivo De Servicio página 46

Ocultar thumbs Ver también para iCAT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 110
3 Product description
Type of voltage
Polarity of the electrodes
Wire types
Type of use
Voltage rating
Protection type of the
machine-side connections
Shielding gas (DIN EN 439) CO
Tab. 8
General torch data according to EN 60 974-7
Type
®
ABIROB
A300
®
ABIROB
A360
®
ABIROB
A500
®
ABIROB
350GC
®
ABIROB
W300
®
ABIROB
W500
ROBO WH 242 D
ROBO WH W500
ROBO WH 652 D TS liquid
Tab. 9
Product-specific torch data (EN 60 974-7) in connection with iCAT
1For pulse arcs, the load data are reduced by up to 35%.
EN - 10
®
ABIROB
A
or M21
2
The following data only apply in connection with the iCAT:
1
Type of
Load
Duty
cooling
cycle
CO
M21
2
A
A
%
air
300 250 100
air
320 290 100
air
350 320 100
air
350 300 100
liquid
320 300 100
liquid
360 340 100
liquid
320 280 100
liquid
360 340 100
360 340 100
The load data was determined under standard conditions, at low to medium
reflected heat, free air circulation and about 28°C of ambient temperature.
When used under more rigorous conditions, the load data must be reduced
by 10-20%.
Applications above 360A are possible in connection with the liquid-cooled
®
torches ABIROB
W500, ROBO WH W500 and ROBO WH 652 D TS using
a special liquid cooled power cable, which is only available upon request.
®
ABIROB
GC ABIROB
DC
Usually positive
commercially available round wires
automatic
Peak value of 141 V
IP3X (EN 60 529)
CO
or M21
CO
2
2
ø
Wire
Gas
flow
mm
l/min
0.8 - 1.4 10 - 20 800
0.8 - 1.4 10 - 20 800
0.8 - 1.6 10 - 20 800
0.8 - 1.2 ca. 20
0.8 - 1.2 ca. 20
0.8 - 1.6 ca. 20
0.8 - 1.2 ca. 20
0.8 - 1.6 10 - 20 800
1.0 - 1.6 10 - 20 800
®
W ROBO WH
or M21
CO
or M21
2
Cooling data
Cooling
flow
Flow
capacity
pressure
min.
min
min
W
l/min bar
-
-
-
-
-
-
800
-
-
800
1
1.5
800
1
1.5
800
1
1.5
1
1.5
1
1.5
iCAT
max
bar
-
-
-
-
3.5
3.5
3.5
3.5
3.5
Tabla de contenido