a movement from a limit switch. Warning! - It is advisable to programme a slightly longer duration (by a few seconds) with respect to the time
necessary to complete the manoeuvre.
• What is the "Pause Time"? It is the time for which the control unit waits to re-close the door automatically, once the user has sent an opening
command (function: automating re-closing). The programmable Pause Time lasts from 5 seconds (minimum) to 120 seconds (maximum). The
Pause Time can also be eliminated entirely: this serves to disable automatic re-closing.
To memorise the "Work Time" and the "Pause Time"
01.
Bring the door to the low limit switch.
02.
Press and hold button T1 on the control unit: as soon as the motor starts moving towards the high limit switch, start counting 5 sec-
onds. At the end of the 5 seconds the control unit will start memorising the duration of the manoeuvre;
03.
Continue holding button T1; wait for the manoeuvre to end at the high limit switch; wait a few seconds more and then release the but-
ton. The motor will stop and the control unit will memorise the new Work Time that has just been counted.
04.
Within 2 seconds from the motor's stoppage, press and hold button T1 on the control unit: from this moment the Pause Time will start
being measured.
05.
Release button T1 after the desired time has elapsed (maximum 120 seconds); the control unit will command the motor to perform a
downward manoeuvre while it memorises the time that has just been measured. This time will subsequently be used for the auto-
matic re-closing of the door.
IMPORTANT - The programmed Pause Time will only be executed if dip-switch 8 is set to ON.
To modify the "Work Time" and the "Pause Time"
01.
To modify the "Work Time" alone, repeat the procedure from the beginning and stop at Step 4.
To disable the "Pause Time"
To disable automatic re-closing and, therefore, eliminate the Pause Time, repeat the procedure from the beginning and stop at Step 4.
01.
Alternatively, the automatic re-closing can be disabled by putting dip-switch 8 to OFF.
English – 12