Specifications • Installation
Risk of electric shock. Can shock, burn
or kill. If your basement has water or moisture on
floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off
service to house, or call your local fire department
for instructions. Remove pump and repair or re place.
Failure to follow this warning can result in fatal
electrical shock.
17. Pump water only with this pump. Do not use with
salt water or brine.
18. Do not install the pump in any location classified as
hazardous by the National Electric Code, ANSI/NFPA
70-1984 or the Canadian Electrical Code.
Specifications
Power supply required. . . . . . . . . . . . . . . . . . . . . . 115V, 60 HZ.
Liquid Temp. Range. . . . . . . . . . . . . . . . 32°F to 130°F (0°-54°C)
Horsepower MCI033M Series . . . . . . . . . . . . . . . . . . . . .1/3 HP
MCI050M Series . . . . . . . . . . . . . . . . . . . . .1/2 HP
Individual Branch
MCI033M Series. . . . . . . . . . . . . . 15 Amps
Circuit Required:
MCI050M Series. . . . . . . . . . . . . . 20 Amps
Full Load Amps MCI033M Series . . . . . . . . . . . . . . . .9.8 Amps
MCI050M Series . . . . . . . . . . . . . . .12.0 Amps
Cord Length . . . . . . . . . . . . . . . . . . . . 20' (6.1 m) or 30' (9.1 m)
Discharge Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/2" NPT
Performance
GPM (LPM) at total feet (m)
Model
5 (1.5m)
10 (3)
Capacity gallons (liters)/minute
MCI033M
48 (182)
40 (151)
MCI050M
62 (235)
52 (197)
Installation
1. Install the pump in a sump pit with a minimum
diameter of 10" (254mm). The sump depth should be
15" minimum (381mm). Construct the sump pit of
tile, concrete, steel or plastic. Check the local codes
for approved materials.
2. The pump should not be installed on clay, earth or
sand surfaces. Clean the sump pit of small stones
and gravel which could clog the pump. Keep the
pump inlet screen clear.
15 (4.6)
20 (6.1)
25 (7.6)
29 (110)
15 (57)
-
45 (170)
39 (148)
29 (110)
3. Install the discharge plumbing. When using rigid
pipe, use plastic pipe. Wrap the threads with PTFE
pipe thread sealant tape. Screw the pipe into the
pump hand tight +1 – 1-1/2 turns.
NOTICE: Do not use ordinary pipe joint compound
on plastic pipe. Pipe joint compound can attack
plastics and damage the pump.
injury and/or property damage.If a flexible discharge
hose is used, make sure the pump is secure in
the sump to prevent movement. Failure to secure
the pump may allow pump movement, switch
interference and prevent the pump from starting
or stopping.
4. To reduce motor noise and vibrations, a short length
of rubber hose (e.g. radiator hose) can be connected
into the discharge line near the pump using
suitable clamps.
5. Install an in-line check valve to prevent backward
flow through the pump when the pump shuts off.
6. Power Supply: The pump is designed for 115 V.,
60 Hz., operation and requires a minimum 15 amp
(1/3 HP) or 20 amp (1/2 HP) individual branch
circuit. The pump is supplied with a 3-wire cord set
with grounding-type plug.
or kill. The pump should always be electrically
grounded to a suitable electrical ground such as a
No flow
grounded water pipe or a properly grounded metallic
at height
shown
raceway, or ground wire system. Do not modify the
below
cord or plug or cut off the round ground pin.
24 ft.
7. If the pump discharge line is exposed to an outside
(7.3m)
sub-freezing atmosphere, the portion of the line
32 ft.
exposed must be installed so any water remaining in
(9.8m)
the pipe will drain to the outfall by gravity. Failure to
do this can cause the water trapped in the discharge
to freeze which could result in damage to the pump.
8. After the piping and check valve have been installed,
the unit is ready for operation.
9. Check the operation by filling the sump with
water and observing pump operation through one
complete cycle.
injury and/or property damage. Failure to make this
operational check may lead to improper operation,
premature failure, and flooding.
Risk of flooding. Can cause personal
Risk of electric shock. Can shock, burn
Risk of flooding. Can cause personal
4