Specifications
Measurement Range
Frequency
Beam Angle
Environmental
Location
Maximum Altitude
Ambient Temperature
Ambient Pressure
Pollution Degree
Construction
Housing
Mounting
Cable
Weight**
Maximum separation
from transceiver
Supply Source
Approvals
*
Approximate shipping weight of transducer with standard cable length.
** EMC performance available upon request .

Outline and Dimensions

safety connection
9mm (3/8") dia. hole
(2places)
Page EN-4
XLT Series Transducers – OPERATION MANUAL
XLT-30
0.9 - 30 m
(3 - 100 ft)
22 KHz
indoor/outdoor
2000 m
-40 to 150 °C
(-40 to 300 °F)
N. America: up to 1000 kPa (1 bar, 15 psi)
Europe:
up to 50 kPa (0.5 bar, 7.25 psi)
4
aluminum, 304 stainless steel,
and silicon
1" NPT conduit connection
2-wire shielded/twisted,
2
0.5mm
(20 AWG) Silicone
jacket
6.6 kg
(14.5 lb)
365 m
(1200 ft)
Transducers shall only be supplied by Siemens Milltronics certified
controllers
CE**, CSA, FM, SIRA/CENELEC
See nameplate or consult Siemens Milltronics for current approvals
1" NPT
earth connection screw clamp (1 place)
h (nominal)
d
XLT-60
1.8 - 60 m
(6 - 200 ft)
13 KHz
indoor/outdoor
2000 m
-40 to 150 °C
(-40 to 300 °F)
4
aluminum, 304 stainless steel,
and silicon
1" NPT conduit connection
2-wire shielded/twisted, 0.5mm
(20 AWG) PVC jacket
6.6 kg
(14.5 lb)
365 m
(1200 ft)
XLT-30
h
249 mm (9.8")
d
264 mm (10.4")
2
XLT-60
324 mm (12.75")
335 mm (13.2")
7ML19985QS81