AUTOMATIC START & STOP CONTROL
NOTE
Automatic Start & Stop Control is intended for use
when the motor will start no more than 6 times per
hour .
When the receiver tank pressure reaches the factory pre–set
maximum pressure, the pressure switch stops the unit . When
the receiver tank pressure drops below the factory pre–set
minimum, the pressure switch resets and restarts the unit .

dUAL CONTROL

Select either automatic start and stop control or constant
speed control by adjusting the knob on the auxiliary valve .
For automatic start and stop control, turn the knob on the
auxiliary valve fully clockwise to disable the auxiliary valve .
The pressure switch will then start and stop the unit .
A . Knob
B . Clockwise
C . Counterclockwise
80447113 Rev.A

OPERATING INSTRUCTIONS

1
22505309 REV . A
Auxiliary Valve .
Select constant speed control if the unit restarts in less
than 10 minute intervals or runs more than 40 minutes per
hour . Turn the knob fully counterclockwise to run the unit
2
continually .
NOTE
The auxilIary valve is factory pre–set at 5 psig (0,3 bar)
lower than the factory pressure switch setting .
Running unloaded with no air demand, will cause the
unit to be shutoff by the pressure switch .
CAUTION
7