IMPORTANT: Always place the gasket between the hob fitting and the connection
pipe.
If using a stainless steel flexible pipe, it must be installed so that it does not
come in contact with any part of the cabinet, but passes through an unoccupied
area where its entire length can be inspected. Maximum extension of the flexible
pipe must be less than 2 metres.
The gas fitting is the type with a 1/2" gas ISO R7 tapered thread.
After connecting the appliance to the gas supply network always verify fittings
seal using a soapy solution.
VERIFYING THE SEAL USING NAKED FLAMES IS ABSOLUTELY PROHIBITED.
The cooker hob is tested for methane gas G20 (2H) at a pressure of
20 mbar. For supplying with other types of gas, see the Adapting to the different
types of gas table
8.1
Connection to liquid gas
Use a pressure regulator and realise connection on cylinder in compliance with the
prescriptions established by the current Standards.
Ensure the supply pressure respects the values indicated in the table
Adapting to different types of gasses
must be carried out with copper rigid pipe or with stainless steel flexible pipe with
continuous wall.
9.

Room ventilation

IMPORTANT: The appliance can only be installed in rooms that are permanently
ventilated, as required by standards in force.
[
]