FIGURE 3: Heatstar AG Dimensions & Suggested Mounting Heights
9.25"(23.49cm)
9.25"(23.49cm)
Burner Rear View
Model #
COMFORTER-40
COMFORTER-60
COMFORTER-80
COMFORTER-80
COMFORTER-100
COMFORTER-100
COMFORTER-125
COMFORTER-125
COMFORTER-150
COMFORTER-150
COMFORTER-175
COMFORTER-175
Heat Exchanger Tubing
17.75"(45.08)
Burner Side View
Burner Ratings and Heat Exchanger Lengths: (NG and LP)
Rate
Heat Exchanger
(BTU/Hr.)
Length
40,000
10 ft. (3.05 m)
60,000
20 ft. (6.1 m)
80,000
20 ft. (6.1 m)
80,000
30 ft. (9.15 m)
100,000
30 ft. (9.15 m)
100,000
40 ft. (12.2 m)
125,000
40 ft. (12.2 m)
125,000
50 ft. (15.25 m)
150,000
50 ft. (15.25 m)
150,000
60 ft. (18.3 m)
175,000
50 ft. (15.25 m)
175,000
60 ft. (18.3 m)
Enerco | Heatstar AG Series Heater
Minimum Total Length (see chart below)
Reflector
Turbulator
9 ft. (2.75 m)
10 ft. (3.05 m)
10 ft. (3.05 m)
10 ft. (3.05 m)
5 ft. (1.5 m)
None
None
None
None
None
None
None
E-10
Operating Instructions and Owner's Manual
Turbulator
(some Models)
Minimum
Total Length
1 1 ft. 4" (3.45 m)
21 ft. 4" (6.50 m)
21 ft. 4" (6.50 m)
31 ft. 4" (9.55 m)
31 ft. 4" (9.55 m)
41 ft. 4" (12.60 m)
41 ft. 4" (12.60 m)
51 ft. 4" (15.65 m)
51 ft. 4" (15.65 m)
61 ft. 4" (18.69 m)
51 ft. 4" (15.65 m)
61 ft. 4" (18.69 m)