73 00
Safety edge 1 configuration
00
NOT PRESENT
01
SWITCH, only reverses when opening
02
8k2, only reverses when opening
03
SWITCH, always reverses
04
8k2, always reverses
74 00
Safety edge 2 configuration
00
NOT PRESENT
01
SWITCH, only reverses when closing
02
8k2, only reverses when closing
03
SWITCH, always reverses
04
8k2, always reverses
75 01
Encoder configuration
00
NOT PRESENT
01
OPTICAL (8 pulses per revolution)
02
MAGNETIC (1 pulse per revolution)
In the absence of an encoder, control is performed on the basis of the work time.
Most ROGER motors with an encoder use optical encoders, only the E30 series uses magnetic
encoders (in case of doubt please read the instructions carefully or contact customer support).
76 00
1st radio channel configuration
77 01
2nd radio channel configuration
00
PP
01
PEDESTRIAN
02
OPEN
03
CLOSE
04
STOP
05
COURTESY the relay is only driven by the radio, it is deactivated in normal operation
COURTESY PP (turn light on-off) the relay is only driven by the radio, it is deactivated in
06
normal operation
07
FLASHING LIGHT relay is controlled only by the radioreceiver, is disabled in normal operation
FLASHING LIGHT PP (ON-OFF Light) relay is controlled only by the radioreceiver, is disabled in
08
normal operation
78 00
Flashing configuration
00
FIXED (the intermittent operation is carried out by the electronics of the flashing)
01
slow intermittent activation
02
slow intermittent when opening; quick intermittent activation when closing
NOTE: parameter
the flashing starts when there is a movement phase; you can have continued activation (for flashing
lights with electronics timed on-board) or controlled directly by the control unit (for flashing lights
with a simple lamp).
7-
in simplified mode
35