PASSO-PASSO (PP)
00
OPENS - STOPS - CLOSES - STOPS - OPENS
01
PP CONDOMINIUM, command PP refreshes the rest time from fully opened
02
PP CONDOMINIUM, command PP closes from fully opened
03
OPENS – CLOSES – OPENS - CLOSES
04
OPENS – CLOSES – STOPS – OPENS
NOTE: parameter
Condominium means that the command PP is ignored when opening.
In installations where multiple users may arrive at the same time, and therefore trigger the radio
control while the gate is operating, is useful to ensure the completion of the opening: it is possible to
prevent two activations by different users from reversing the motion by closing the gate.
ATTENTION: by setting condominium mode (value
relocking (parameter
By setting the parameter to the value
command does not perform a closure but restarts the count of the rest time.
A5 00
Pre-flashing
00
OFF (the flashing light is only on when there is movement)
01
10
DURATION IN SECONDS of the early activation of the flashing
-
99
not performed when opening; 5 seconds of pre-flashing when closing
NOTE: parameter 5- in simplified mode
A6 00
Condominium function with PEDESTRIAN (PED)
00
OFF (pedestrian control performs AP-ST-CH-ST-AP- ...)
01
ON (pedestrian control operated when opening is ignored)
A7 00
Man present
00
OFF (the controls work normally)
01
ON (the gate only moves by holding down AP or CH)
The motors will only remain active in the presence of a continued command; only the commands AP
and CH are enabled; the motors will stop upon release of the command.
The commands must be positioned so as to be able to check the movement of the gate.
A8 00
Gate open light
00
when the gate is closed the light is off, otherwise it is on
slow flashing when opening, quick when closing, fixed from fully open, turns off 3 times in
01
succession every 15 seconds if the gate has stopped in the intermediate position
02
the SC output is used to supply power to the photocells and perform the test on them
11 15
Length travelled in slowdown
01
30
PERCENTAGE of the total stroke
-
If the slowdown is enabled (parameter
cover - with respect to the total - at the slowed down speed.
WARNING! If the encoder is not being used, this choice must be made before starting to programme
the stroke. If it is done after programming, it will be necessary to proceed with a new programming.
6-
in simplified mode
A2
).
01
and
01
, if the gate is open, the activation of the step-by-step
41
00
different from
02
) automatically activates automatic
), it determines how much space it will