13 10
Tolerance of the position in which the leaf is considered fully open or closed
01
40
rpm
-
Establishes the maximum tolerance in the control of the full opening and closing position (where
there is a motor stop). Too narrow a setting is likely to cause the reversal of the motion when the
leaf arrives at the stop.
The parameter is only visible if 1 or both limit switches are not present (
and the encoder is enabled (
15 30
Pedestrian stroke length
01
99
PERCENTAGE of the total stroke
-
16 00
Margin of recovery for timed operation
00
3 seconds
01
seconds (useful for hydraulic motors, with higher inertia)
In the timed operation: programming the work time it is a good idea to always set a safety margin
(3-4 seconds) to be sure that the manoeuvre is always complete, even when changing the weather
conditions (wind, low temperature). When you reverse the motion, for example upon activation of
the photocells, the activation of the motor in the opposite direction takes place for the exact time
that was spent in motion plus a safety margin (recovery inertia).
In the case of hydraulic motors, with greater inertia, it is possible to increase this margin for a greater
guarantee of manoeuvre completion from the standard value of 3 seconds to the increased value of
6 seconds.
The parameter is only visible if the encoder is disabled (
21 30
Pause time for automatic reclosing
00
90
SECONDS
-
92
99
from 2 to 9 MINUTES
-
NOTE: parameter
When one of the photocells is obscured the timer is reset and the count restarts upon the return of
the safety protection at pause.
22 20
Work time
00
99
SECONDS of manoeuvre
-
The parameter is only visible if the encoder is disabled (
24 00
Doubling work time
00
OFF (normal manoeuvre time)
01
ON (doubling of the manoeuvre time)
Used for installations with particularly long work times.
The parameter is only visible if the encoder is disabled (
27 02
Time taken to move back after the intervention of the safety edge or the anti-crushing protection
00
60
SECONDS
-
Establishes how many seconds the reversal operation on obstacle lasts; set to a value high enough
to reach the opening limit switch it also performs automatic reclosing according to parameter
30
75 01
2-
in simplified mode
75 02
or
).
75 00
75 00
75 00
72 00
or
).
).
).
72 02
)
49
.