HeatStar HS25NG Instrucciones De Uso Y Manual Del Usuario página 12

Calentador infrarrojo a gas para taller
Ocultar thumbs Ver también para HS25NG:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CHAPTER 4
OPERATING MAINTENANCE
INSTRUCTIONS
1. TROUBLESHOOTING
A. Table 4 lists the common malfunctions which you
may find during the operation or maintenance of
your heater.
B. In the event results cannot be obtained after
performing all listed solutions, call the factory.
2. ADJUSTING THE PILOT FLAME
The pilot flame should envelop 3/8 to 1/2 in. (10 to 13
mm) of the tip of the thermocouple or generator. Refer
to Figure 1 1. To adjust:
A. Remove pilot adjustment cover screw. Refer to
Figure 12.
B. Turn inner adjustment screw clockwise
decrease or counterclockwise
flame.
C. Always replace cover screw after adjustment and
tighten firmly to ensure proper operation.
MANUAL GAS
CONTROL KNOB
WRENCH
BOSS
GAS
INLET
PILOTSTAT
POWER UNIT
HEATSTAR Gas Fired Infrared Workshop Heater
to
to increase pilot
PRESSURE REGULATOR ADJUSTMENT
(BENEATH COVER SCREW)
PILOT FLOW ADJUSTING SCREW
(BENEATH COVER SCREW)
Figure 12. Top view of Standard Capacity Gas Control
PROPER FLAME
ADJUSTMENT
Figure 11. Proper Flame Adjustment
3. REPLACING THE GAS VALVE UNIT
A. Remove the two gas valve unit wires at the gas
control valve labeled "PP".
B. Unscrew gas valve from gas piping.
C. Reconnect gas valve and unit wires to terminals
"PP". Be sure to leave thermostat wire on one
terminal.
STANDARD
PRESSURE
REGULATOR
("A" MODEL)
STEP OPENING REGULATOR
("C" MODEL)
PILOT GAS OUTLET
(PRESSURE TAPPING
DIRECTLY BENEATH)
E12
Operating Instructions and Owner's Manual
3/8 TO 1/2 INCH
(10-13 MILLIMETERS)
THERMOCOUPLE
INSTALL LONG
SCREW IN
OUTSIDE CORNER
Tabla de contenido
loading

Este manual también es adecuado para:

Hs22lp

Tabla de contenido