9

MOUNTING - luminaire head

Remove screw and take off the protective
cap
Insert luminaire head.
Turn sleeve to insert securing segment
Turn sleeve back and secure with screw
WARNING
Danger from falling luminaire head.
Ensure that the safety element has been
correctly installed.
An incorrectly mounted luminaire head can
cause injury.
Tighten the luminaire head's friction lock as
required
Attach hand grip.
10

OPERATION

Polaris 50 Mobile
DANGER
Electric shocks are life-threatening.
Do not insert any power cable that is
damaged.
If there is any sign of damage to the power
cable, replace it immediately with a new
one.
The supply voltage and frequency must
match the data on the type plate.
Only connect to the mains power supply
with a protective conductor
NOTE
Polaris 50 Mobile
When the power cable is not in use, reel it
onto the cable holder
1 2
Insert cable 1.
Connect cable to the power supply
Operate switch 2. There are two 1 A fuses
upstream from the switch
WARNING
Risk of eye damage
 Never look directly into the beam of light
Polaris 50 Ceiling, Wall, Mobile, CSU
Switch on luminaire using the rotary knob.
Perform a function test before each use: All
LEDs in the light cone must illuminate
CAUTION
The rotary knob can not be removed.
EN_GB
35