NIOSH Cautions and Limitations

The following restrictions may apply. See NIOSH approval label.
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
D - Air-line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or
higher quality.
E - Use only the pressure ranges and hose lengths specified in the User's Instructions.
G - If airflow is cut off, switch to filter and/or cartridge or canister and immediately exit to clean air.
H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and canisters are replaced before
breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
K - The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against
formaldehyde.
L - Follow the manufacturer's User's Instructions for changing cartridges, canister and/or filters.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
S - Special or critical User's Instructions and/or specific use limitations apply. Refer to User's Instructions before donning.
S – Special or Critical User Instructions
3M™ Organic Vapor Service Life Indicator Cartridges (6001i and 60921i) are equipped with a passive 3M™ End of Service Life Indicator (ESLI). The
indicator must be readily seen when wearing the respirator. If you cannot readily see the ESLI, use a mirror to observe the ESLI; rely on a co-worker
who can see the ESLI; or go to a clean area, remove the respirator and view the ESLI. Do not rely solely on the organic vapor ESLI unless your
employer has determined that it is appropriate for your workplace. See 6001i or 60921i User Instructions for more information, including Special
Instructions regarding the ESLI.
3M™ Mercury Vapor, Organic Vapor and Acid Gas Cartridges (6007 and 60927) must be discarded within 50 hours of use against mercury vapor.
3M™ Particulate Filter P95, Hydrogen Fluoride, with Nuisance Level Acid Gas Relief, 2076HF and 3M™ Particulate Filter P100, Hydrogen Fluoride,
with Nuisance Level Acid Gas Relief, 7093C are recommended for relief against nuisance levels of acid gases or organic vapors. Nuisance level refers
to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower. Do not use for respiratory
protection against acid gases or organic vapors, except hydrogen fluoride.
To assemble 3M™ Dual Airline Combination Breathing Tubes with 3M™ Cartridges/Filters, the facepiece inhalation valves must be removed.
If the facepiece is to be used in air-purifying mode (without using the 3M™ Breathing Tubes SA-1600 or SA-2600), the inhalation valves must be
replaced in the facepiece before use.
Cartridge and Filter Selection and Approvals
Before using any of these products, the user must read the specific use for, use limitations and warning information in the User Instructions and
product packaging or call 3M Technical Service at 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.
Do not exceed maximum use concentrations established by local regulatory agencies. Cartridges/filters are approved as assemblies for use with
3M™ Half Facepiece 7500 Series. For NIOSH approval, refer to approval label.
LIST OF PRODUCTS
3M™ Half Facepiece 7500 Series Replacement Parts and Accessories
3M™ Half Facepiece 7500 Series
Number
****AAD
7501
37081
7502
37082
7503
37083
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers.
Replacement Parts (Fig. 1A)
Number
****AAD
A
7581
B
7582
C
7586
D
7583 or 6583
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
Accessories
Number
****AAD
504
07065
601
6880
37002
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers.
Description
Small
Medium
Large
Description
Head Harness Assembly
Inhalation Valves
Cartridge/Filter Holder
Exhalation Valve
Description
Respirator Cleaning Wipes
Quantitative Fit Test
Adapter
Bayonet Cap
3
Tabla de contenido
loading

Tabla de contenido