Information Provided On The Factory Panel; Staff Training; Obligations Of The Operator - ABB D184B123U01 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2.1.6
The factory tag can be found on the measurement recorder housing. Two different factory labels are used
depending on the nominal size of the pressure equipment (> DN25 / 1" or ≤ DN25/1") (see also Article 3
Paragraph 3 in PED 97/23/EU) :
a) Pressure equipment with nominal sizes > DN25/1"
b) Pressure equipment with nominal sizes ≤ DN 25/1"
2.1.7
2.1.8
D184B123U01
Electromagnetic flowmeter

Information provided on the factory panel

ABB
S.-Nr.: 0012345
DN 50 / PN 40
Material: 1.4571 / PTFE
/ Hast.C-4
Manufactured: 2002 PED: Fluid 1, Gas
ABB Automation Products GmbH
37070 Göttingen - Germany
ABB
S.-Nr.: 0012345
DN 25 / PN 40
Material: 1.4571 / PTFE
/ Hast.C-4
Manufactured: 2002 PED: SEP
ABB Automation Products GmbH
37070 Göttingen - Germany

Staff training

The electrical Installation, start-up and maintenance of the instrument may only be undertaken by a
trained technician who has been authorised to perform these tasks by the system operator. The
technician must have read and understood this operating manual and must follow the instructions
provided in it.

Obligations of the operator

Before using corrosive or abrasive measuring agents, the operator must clarify that all parts which
come into contact with these measuring agents are resistant to such agents. ABB would be happy to
assist you with your selection, but cannot assume liability for any choices made.
Always note the relevant national regulations applicable in your country with regard to function
checks, repairs and maintenance of electrical equipment.
The factory tag contains the following information:
CE symbol (with number of the designated area) to con-
firm equipment conformity with the requirements of the
PED.
0045
Serial number for identification of the pressure equip-
ment by the manufacturer.
Nominal width and nominal pressure stages of pressure
equipment
Flange material, cladding material and electrode mate-
rial (which comes into contact with the measuring
agent).
Year of construction of pressure equipment and infor-
mation about fluid groups to be taken into consideration
in accordance with (PressureEquipmentDirective =
PED) Fluid group 1 = dangerous fluids, fluid, gaseous
(also unstable gases)
Manufacturer of the pressure equipment
The factory tag contains almost the same information as the
tag described under a) with the following differences:
There is no CE mark in accordance with Article 3 Para-
graph 3 of DGRL/PED.
The reason for this exception, Article 3 Paragraph 3 of
the PED is specified on the panel under PED. The pres-
sure equipment is classified within the scope of SEP
(= Sound Engineering Practice).
2 English