You should inspect the air filter in the turbine to see
if it is excessively dirty. If it is dirty, follow the steps
below to replace it.
1. Unplug the spray gun. Push the snap levers (a) on the
two turbine covers and remove them.
2. Remove the dirty filters and replace with new ones. The
smooth side of the air filter must be placed toward the
turbine.
3. Secure the covers back onto the turbine.
Problem
A.
Little or no material flow
B.
Material leaking
C.
Atomization is too coarse
D.
Spray jet pulsates
E.
Pattern runs or sags
F.
Too much overspray
G.
Pattern is very light and
splotchy.
Have you tried the recommendations above and are still having problems? In the United States, to speak to a
customer service representative, call our Customer Service at 1-800-328-8251 Monday through Friday between 8:00
AM and 4:30 PM Central time.
Product Registration
Register your product online at www.wagnerspraytech.com. Proper registration will serve as proof of purchase in the event your
original receipt becomes misplaced or lost.
Maintenance
Troubleshooting
Cause
1.
Nozzle clogged.
2.
Suction tube clogged.
3.
Material volume setting turned too low (-).
4.
Suction tube loose.
5.
No pressure build up in container.
6.
Air filter clogged.
1.
Nozzle loose.
2.
Nozzle worn.
3.
Nozzle seal worn.
4.
Material build-up on air cap and nozzle
1.
Viscosity of material too high.
2.
Material volume too large.
3.
Material volume setting too high (+).
4.
Nozzle clogged.
5.
Air filter clogged.
6.
Too little pressure build-up in container.
1.
Material in container running out.
2.
Air filter clogged.
1.
Applying too much material.
1.
Gun too far from spray object.
2.
Too much material applied.
1.
Moving the spray gun too fast.
Never operate your unit without the air filters. Dirt
could be sucked in and interfere with the function of
the unit.
Solution
1.
Clean.
2.
Clean.
3.
Increase volume setting (+).
4.
Insert.
5.
Tighten container.
6.
Change.
1.
Tighten.
2.
Replace.
3.
Replace.
4.
Clean.
1.
Thin.
2.
Decrease volume setting (-).
3.
Decrease volume setting (-).
4.
Clean.
5.
Change.
6.
Tighten container.
1.
Refill.
2.
Change.
1.
Adjust material flow or increase movement of spray
gun.
1.
Reduce distance.
2.
Decrease volume setting (-).
1.
Adjust material flow or decrease movement of spray
gun.
7
(a)
English