Operation; Controls - Ebasto CC4E Instrucciones De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Roof-top Air-conditioning System CC4E, CC5 and CC8
3

Operation

The system is operated via the 2-position
ON / OFF switch in combination with the
3-position switch for the required fan pow-
er. Both switches have no indication of
their switch position. The optional temper-
ature controller permits selection of the
required temperature.
As an option the integral fresh air valve
can be actuated using the OPEN / CLOSE
switch. When it is open the control light in
the switch (CC8) will be lit.
If the roof-top air-conditioning system CC8
has been installed with optional heating,
the heating will be switched on via a com-
bined heating / air-conditioning switch.
The two-position ON / OFF switch for the
air-conditioning system (top right) will then
be replaced by the combined heating / air-
conditioning switch (bottom right).
12

3.1 Controls

Response to new temper-
!
ature controller settings is
delayed.
Temperature con-
troller (optional)
Rotary control for
setting the cabin
temperature
Temperature con-
troller is replaced if
the optional heating
is installed (CC8)
Red = HEATING
Blue = COOLING
Temperature is not controlled
when the switch is set to 0
2-position ON / OFF switch
for air-conditioning system
(replaced by heating / air-con-
ditioning switch (see below)
when optional heating is in-
stalled)
3 position switch
Fan power
2-position switch
(optional, CC8 only)
Fresh air ventilation flap
OPEN / CLOSED with
indicator for OPEN position
3-position switch
(Only optional on CC8)
Combined heating / air-condi-
tioning switch
ON / OFF / ON
Tabla de contenido
loading

Este manual también es adecuado para:

Cc5Cc8

Tabla de contenido