Operations And Functions - Steinberg Systems SBS-KW-1TE Manual De Instrucciones

Balanzas de grúa
Ocultar thumbs Ver también para SBS-KW-1TE:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

4. OPERATIONS AND FUNCTIONS

4.1 POWER ON
Check that the hook has no goods, turn the mechanical switch at the back of scale to
the ON position and press button [ON/OFF] on the front panel. The system will enter
into self-check mode with the following five displays.
4.1.1
The first display is the version number of the software. E.g. UER 2.0
4.1.2
The second display is all of the indicating symbols to check whether there is
incomplete stroke and whether indicator lamps can light on.
4.1.3
The third display is capacity. For example, 1000 means the max capacity is
1000kg.
4.1.4
The fourth display is the voltage display. E.g. U6.3 means that the current
voltage is 6.3V.
4.1.5
Finally, it displays 0.0 and ready for weighing.
4.1.6
Please do not use the crane scale (LED) under high luminance (like direct
sunshine) and please confirm whether the display is clear when power on.
4.2 WEIGHING OPERATION
EN
When the scale gets steady, it will display "0.0" and the stable indication lamp will light
up. After that, the scale is ready for weighing operation.(Note: it is recommended to
allow scale 15 minutes of warm-up time before starting weighing operation)
Put the load, the scale will display the weight value after 4-5 seconds and the stable
lamp will light up.
Note: The scale will alarm the user by displaying "-OUE-" when the load exceeds 100%
F.S plus 100e. Once the load exceeds 200% F.S, the system will lock automatically and
display "LOC-". It will save the overload record in system and display "UP200" when
restart.
32
4.3 ZERO
The weight window does not display "0" when unloaded, please press key [ZERO] or
Or Press button [D] on the remote.
4.4 MEMORY AND QUERY
Press [MEMORY/QUERY] or button [A] on the remote, the data stored in the scale.
Press [MEMORY/QUERY] or button [A] on the remote four seconds will display "his",
press [MEMORY/QUERY] one by one could display Historical data one by one.
Press [MEMORY/QUERY],button [A] on the remote or static loading four seconds will
exit query state.
4.5 HOLD AND CLEAR
Press [HOLD/CLR] or button [B] on the remote, current data will be lock. Then the
data flicker, press [HOLD/CLR] or button [B] on the remote again, it will release lo-
cked data.
Press [HOLD/CLR] or button [B] on the remote for four seconds, it will display "del"
and historical data will be delete
4.6 POWER OFF
When you finish operation, push button [ON/OFF] for 2 seconds to enter into power
off mode by displaying ——OFF——. Cut off power supply after you loosen the key.
Or Press button D on the remote over 3 seconds and loosen it to power off when the
scale displays "-OFF-". Please turn off the mechanical switch on the back if you do not
use the crane scale for a long time.
4.7 TARE AND UNIT CONVERSION
Press [UNIT/TARE] or button [C] on the remote, it will display "0" and tare indication
lamp will light up.
Changing the unit from "kg" to "lb" by using front panel buttons:
Press [UNIT/TARE] for four seconds, it will display "Lo9" first and then (without relea-
sing button [UNIT/TARE]) press button [MEMORY/QUERY]. Now release the button
[UNIT/TARE] ] and display will show "Lb", and then release [MEMORY/QUERY] but-
ton. The indication lamp "lb" will light up.
Changing the unit from "lb" to "kg" is realized in the same way described above.
Changing the unit from "kg" to "lb" by using the buttons on the remote control:
Press the buttons C and A simultaneously for four seconds. Display will show "Lo9".
Release both buttons, display will show "Lb". The indication lamp "lb" will light up.
Changing the unit from "lb" to "kg" is realized in the same way described above.
33
EN
Tabla de contenido
loading

Este manual también es adecuado para:

Sbs-kw-3/1kSbs-kw-5/2k

Tabla de contenido