2.5 SOFTWARE CALIBRATION
The scale has the advanced software to support fast, rapid and convenient calibration.
2.6 AUTO TARE
The scale will go through automatic tare after power on if there is any container loaded.
2.7 POWER SAVING
The scale will enter into power save mode after 5-minute inactivity. It will power off
automatically after it's inactive for 30minutes.
3. TECHNICAL SPECIFICATIONS AND PARAMETERS

3.1 MAIN SPECIFICATIONS

Table 1
Accuracy Class
Display
Manual Zero/ tare range
EN
Overload alarm
Power supply
Adaptor
Working temperature
Working Humidity
OIML III
Super bright 5-digit 30mm LED
100%F.S
100% F.S.+100e
6V/4Ah rechargeable Lead-Acid battery
DC12V, 1000mA
-10°C~ 70°C
≤90%RH when under 20°C working
temperature
30

3.2 TECHNICAL PARAMETERS

Rated capacity, resolution, division, maximum capacity, minimum capacity, zero set range,
tare range, zero tracking range and limit display (overload alarm) are shown in table 2:
Table 2
Rated capacity
Resolution(Standard)
Standard division (e)
Hi-resolution division
Max capacity
Min capacity
Zero range
Tare range
Zero tracking range
Limit display
Note e=d=standard division
3.3. ERROR RANGE
Table 3
weight
(described as e)
Outgoing inspection
0≤m≤500e
±0.5e
500e<m≤2000e
±1.0e
2000e<m≤3000e
±1.5e
1000kg
3000 kg
5000 kg
1/2000
1/3000
1/2500
500g
1kg
2kg
200g
500g
1kg
1000kg
3000kg
5000kg
20d
20d
20d
±60d
±60d
±60d
Max
Max
Max
±0.5d
±0.5d
±0.5d
Max+9d
Max+9d
Max+9d
Error range
Inspection after repair
±1.0e
±2.0e
±3.0e