Selecting The Mounting Position; Installation Diagram; Indoor Unit - Fujitsu AOYG12-14LBLA Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20

3. SELECTING THE MOUNTING POSITION

With considering written conditions below, select an appropriate installing location in
consultation with the customer.
Securely install the outdoor unit at a location that can withstand the weight of the unit.
Otherwise, the outdoor unit may fall and cause injury.
Be sure to install the outdoor unit as prescribed, so that it can withstand earthquakes
or strong winds. Improper installation can cause the unit to topple or fall, or other
accidents.
Do not install the outdoor unit in the following areas:
• Area with high salt content, such as at the seaside. It will deteriorate metal parts,
causing the parts to fail or the unit to leak water.
• Area fi lled with mineral oil or containing a large amount of splashed oil or steam. It will
deteriorate plastic parts, causing the parts to fail or the unit to leak water.
• Area that generates substances that adversely affect the equipment, such as sulfuric
gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to
corrode, which can cause refrigerant leakage.
• Area containing equipment that generates electromagnetic interference. It will cause
the control system to malfunction, preventing the unit from operating normally.
• Area that can cause combustible gas to leak, contains suspended carbon fi bers or
fl ammable dust, or volatile infl ammables such as paint thinner or gasoline. If gas leaks
and settles around the unit, it can cause a fi re.
• Area that has heat sources, vapors, or the risk of the leakage of fl ammable gas in the
vicinity.
• Area where small animals may live. It may cause failure, smoke or fi re if small ani-
mals enter and touch internal electrical parts.
• Area where animals may urinate on the unit or ammonia may be generated.
(1) If possible, do not install the unit where it will be exposed to direct sunlight.
(If necessary, Install a blind that does not interfere with the air fl ow.)
(2) Do not install the unit where a strong wind blows or where it is very dusty.
(3) Do not install the unit where people pass.
(4) Take you neighbors into consideration so that they are not disturbed by air blowing
into their windows or by noise.
(5) Provide the space shown in fi gure so that the air fl ow is not blocked. Also for ef-
fi cient operation, leave open three of the four directions front, rear, and both sides.
(6) Install the unit where keep away more than 3m from the antenna of TV set and
Radio.
(7) Outdoor unit should be set to a place where both drainage and itself will not be af-
fected when heating.
• When there are obstacles at the back side.
AIR
• When there are obstacles at the back and front sides.
• When there are obstacles at the back, side(s), and top.
En-3
WARNING
CAUTION
AIR
* If the space is larger than that is stated, the condition will be the same as that there are
no obstacles.
• When there are obstacles at the back side with the installation of more than one unit.
AIR

4. INSTALLATION DIAGRAM

[OUTDOOR UNIT]
Bolt
Nut
Outdoor unit
bottom
Drain hose
AIR

INDOOR UNIT

5 cm or over
• Fix securely with bolts on a solid
block. (Use 4 sets of commercially
available M10 bolt, nut and washer.)
Block
• Do not directly install it on the ground,
otherwise it will cause failure.
54 cm
Power
supply
cable
Tabla de contenido
loading

Tabla de contenido