Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1
Press MENU until the SET UP 3 display appears
on the screen.
<SET UP 3>
ALARM MODE
ALARM SPEED
ALARM DURATION
TAPE IN MODE
TAPE END MODE
TAPE END OUT
CLOG DETECT.
2
Press SHIFT v to move the flashing to TAPE END
OUT and set to –3M or END by pressing DATA
/ .
3
Press PAUSE to return to the normal display.

SW OUT Terminal

The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
COM terminal
SW OUT terminal
Specify the interval between each pulse signal on the
SET UP 4 display. Also, set TIMING to FIELD or
FRAME depending on the specifications of the camera
switcher.
Available settings are:
FIELD: 1, 2, 3, 4, 5, 10, 30, or 60 fields
FRAME: 1, 2, 3, 4, 5, 10, 30, or 60 frames
Y1
2H
20S
STOP
REW
-3M
Y
1
Press MENU until the SET UP 4 display appears
on the screen.
<SET UP 4>
∗SW OUT
FIELD
01
TIMING
FIELD
2H
Y
<USED TIME>
01 of FIELD is flashing.
2
Set the interval by pressing DATA
SHIFT b.
<SET UP 4>
∗SW OUT
FIELD
04
TIMING
FIELD
2H
Y
<USED TIME>
3
Set TIMING to FIELD or FRAME by pressing
DATA
/ .
<SET UP 4>
∗SW OUT
FRAME
04
TIMING
FRAME
2H
Y
<USED TIME>
4
VIDEO
00000H
Set 2H (2-hour mode) to Y (yes) or N (no) by
pressing DATA
/ .
Y (yes): a signal is output in the 2-hour mode
N (no): a signal is not output in the 2-hour mode
5
When you have completed the settings, press
PAUSE to return to the normal display.
/
and press
31
Tabla de contenido

Solución de problemas

loading

Tabla de contenido