Advanced Menu List; Sleepcube Enable Menu List - DeVilbiss Healthcare SleepCube AutoAdjust CPAP DV54 Serie Guía De Instrucciones

Dispositivo de presión positiva en las vías respiratorias
Ocultar thumbs Ver también para SleepCube AutoAdjust CPAP DV54 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
aDVancED mEnu controlS

Advanced Menu List

Display Example
Mode
P: 5.0
Auto
Heat:Off
Upper Limit
AutoAdjust
15.0 cmH20
Lower Limit
AutoAdjust
5.0 cmH20
Set Pressure
10.0 cmH20
Delay Time
45 minutes
Delay Pressure
5.0 cmH20
Tubing Length
1.8 m (6 ft)
Enable Menu
Press 
LCD Contrast Adj
50 %
Compliance Meter
123456.7 hours
Hourmeter
123456.7 hours
Firmware Version
V0.01 01/06/2006
Serial Number
HD123456
Adherence Score
83% (25/30)
SmartCode 1-Day
G201-0Y7-6GPH

SleepCube Enable Menu List

The Enable menu is available in all modes and is a sub-menu that allows you to control various functions of your SleepCube. It is accessed by
pressing the down button while in this Advanced Menu.
Display Example
Description
This option controls the Auto-ON feature, which automatically starts the flow of air after breathing once or twice
Auto-ON
into the mask.
Enabled
Description
This is the default screen when the SleepCube is turned on. The actual mask pressure and heater setting
are shown. The displayed pressure may vary slightly while breathing. If the heater system is not
All
connected, the heat setting will be blank.
This is a prescription setting which limits the maximum pressure at which the SleepCube will operate if
in AutoAdjust mode. Your home care provider programs this setting for you during device setup.
Mode
This is a prescription setting which sets the minimum pressure at which the SleepCube will operate in
AutoAdjust mode. Your home care provider programs this setting for you during device setup.
Mode
This is a prescription setting which controls the operating pressure.
CPAP
Mode
Selectable delay time setting. Your provider has set the delay time. If the unlocked symbol is shown, you
are able to adjust this setting. If the locked symbol is shown, this setting can only be adjusted by your
All
provider.
This is a prescription setting which controls the operating pressure during the delay time.
CPAP
Mode
The standard tubing length supplied with the device is 6 feet (1.8 meters). However, you can adjust your
SleepCube to accommodate an air supply tubing length of 10 feet (3.0 meters). Replacement tubing can
All
be obtained through your home care provider (part numbers listed at the end of this manual).
Pressing the down key enters the Enable menu. Refer to next section for Enable Menu details.
All
This setting changes the contrast for the LCD display. This only needs to be adjusted if you find it difficult
All
to see the display from your viewing angle.
The total number of hours (in 1/10 hour increments) that the SleepCube has been providing therapy.
All
The total number of hours (in 1/10 hour increments) that the SleepCube has been in operation.
All
Shows version of installed firmware.
All
Shows the serial number of the device.
All
All
Shows the maximum adherence achieved for any period of thirty consecutive days of use within a ninety-
day time frame. The score represents the percentage of days, within thirty consecutive days, where
usage met or exceeded the 'Usage Threshold.'
SmartCode
is used for therapy management reporting; therapy information is encoded in a series of
TM
letters and numbers, and includes a special character for error checking to ensure accuracy. Use the UP
All
arrow or DOWN arrow keys to change the SmartCode reporting period.
EN
SE-DV54
9
Tabla de contenido

Solución de problemas

loading

Tabla de contenido