High Altitude Operation - Honda ECM2800 Serie Manual De Instrucciones

Generador de baja potencia
Ocultar thumbs Ver también para ECM2800 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
OM ECM2800-ECMT7000.book Page 5 Mercredi, 29. février 2012 12:00 12

HIGH ALTITUDE OPERATION

At high altitude, the carburettor air / petrol mixture is very rich,
causing a drop in engine performance and an increase in fuel
consumption.
When using the generator at an altitude of over 1 800 metres above
sea level, a smaller diameter jet needs to be fitted to the carburettor
and the pilot screw adjusted. This must be carried out by your
Honda dealer.
In spite of a proper adjustment to the fuel feed system, engine
power will still decrease by 3.5 % for every 300 metre increase in
altitude.
GENERATING SET USE
Your Honda generator is a reliable piece of equipment, developed
to ensure your safety. It can help you carry out work more easily and
bring improvements to your leisure time, but there is also a risk of
electrocution if you do not follow strictly the instructions for use
given in this chapter.
The generator produces
enough electric power to cause
a serious shock or electrocution
if misused. Be sure to ground
the generator [1] when the
connected appliance is
grounded.
To ground the terminal of the
generator, use a cooper wire
with same or larger diameter
than the cord of the connected
appliance.
Use extension cord set with
ground conductor when connecting an appliance with ground
conductor.
To identify the Ground pin in the plug, see "Receptacle"
Connect a RCBO (Residual current circuit breaker with overload
protection) of 30 mA ground fault detection and cut-off of less than
0.4 seconds at more than 30 A of out put current, if you are using
two or more appliance.
Follow the instructions provided by each RCBO manufacturer
before use.
[2]
[4]
[5]
RCBO
Connecting with one RCBO
[2]
[3]
Connecting with two RCBO
• Improper connections to a building's electrical system can
allow current from the generator to backfeed into the utility
lines. Such backfeed may electrocute utility company
workers or others who contact the lines during a power
outage, and the generator may explode, burn, or cause fires
when utility power is restored.
Consult the utility company or a qualified electrician prior to
making any power connections.
• Do not connect any appliances to the receptacles before
• Do not alter the internal wiring of the generator.
• Do not alter the engine settings: the voltage and frequency
• Only connect appliances in good working order: most
• Supply only machines whose voltage, as specified on their
8
9
10
SAFETY
• Due to high mechanical stresses only tough rubber-
• The generator meets the protective measure "electrical
[1]
page
6.
• Electric extension cables must be carefully selected, fitted
[3]
[5]
[4]
RCBO
RCBO
Generator
[4]
• Value for an admissible voltage drop on-line of 7 V and an
[5]
Appliances
starting the generator.
of the generator output are directly linked to the engine
speed; these settings are adjusted in the factory.
portable electrical tools are Class II (double insulation).
Equipment that does not meet this standard (tools with
metallic casing) has to powered via 3 conductor cable (with
an earth conductor) to ensure correct earthing in the event of
an electrical fault.
rating plates, corresponds to that produced by the
generator.
sheathed flexible cable (in accordance with IEC 245-4) or the
equivalent should be used.
separation with equipotential bonding "as stated in the
IEC 60364-4-41 : dec 2005 §413. (and VDE0100 part 728).
- The used power system is the IT system
- with neutral conductor N (for 3 phase machine) and
- non earthed equipotential bonding conductor PE,
connecting all exposed conductive parts of the
generator together.
- Earthing of the generator is for the proper function of this
protective measure not required.
- Only connect appliances in good working condition; most
portable electrical tools are Class II (double insulation).
Equipment that do not meet this standard (tools with
metallic casing) have to be powered via 3-conductor cable
(equipotential conductor PE conductor).
- If the neutral conductor shall be earthed anyway, this may
only be performed by a professional electrician,
implementing the additional safety devices required
together with the new protective measure
(cf. IEC 364-4-41).
and maintained. Good condition insulators will ensure the
safety of the user. Cables must be inspected regularly; they
should be replaced, and not repaired, in the event of a defect.
Choose the length and cross-section of the extension cables
according to the work to be done (see table below for
indications).
Cable
Max. Length
Current
2
(m)
(A)
(mm
)
1.5
25
10
2.5
40
16
4
60
28
admissible current of 7 A per mm
- ambient temperature: 20° C,
- completely unwind the cable to avoid deterioration of the
insulation by over-heating,
- comply with the cable manufacturer's instructions.
Single-phase
Three-phase
(kW)
(kW)
(Cos  = 1)
(Cos  = 0,8)
2.3
5.5
3.7
8.8
6.5
15.5
2
of cable section:
5 EN
Tabla de contenido
loading

Tabla de contenido