Fireplace Installation - Dimplex DF2426GB Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fireplace Installation

1.
Install the fireplace assembly
into the mantel. (refer to
mantel assembly instructions)
!
NOTE 1: A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if, after installation,
the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating.
Additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
!
IMPORTANT: If not using a
Dimplex mantel, the fireplace
must be installed in an
enclosure with the following
MINIMUM internal/opening
dimensions (Figure 1).
New Wall Construction
CAUTION: Clearance for air
circulation beneath the fireplace
insert is provided by two (2)
rubber feet. Do not install the
fireplace directly on carpet
or similar surfaces which
may restrict air circulation.
If installing the fireplace in a
carpeted area, place a one-piece,
8
Figure 1
8 ⅞"
(225.5 mm)
solid, flat surface under the
fireplace insert. Ensure that both
of the insert's feet rest securely
on this surface.
1.
select a suitable location that
is not susceptible to moisture
and is away from drapes,
furniture and high traffic.
2.
Place the fireplace in the
desired location to see how it
will look in the room.
3.
mark the desired location
on the floor and store the
fireplace in a safe, dry and
dust free location.
4.
Use studs to frame an
opening of 24 ½ inches (622
mm) wide X 18 ¼ inches
(463.6 mm) high X 8 ⅞ inches
(225.5 mm) deep. (Figure 1)
24 ½"
(622 mm)