Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 261

Terminadora de firmes
Tabla de contenido
KWP
SPN
FMI
1267
0
1269
1
1268
0
1270
1
1279
9
1283
9
1324
13
1325
13
1327
4
1328
12
1333
3
1335
4
1329
5
1334
3
1336
4
1330
5
1343
12
1344
12
1419
0
1421
1
1420
0
Code
Error Identification
7-2-4
Fuel Balance Control integrator injector 7
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 7
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 8
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 8
(in firing order); minimum value
exceeded
Timeout Error of CAN-Receive-Frame
DM19Vol1; NOX sensor upstream
Timeout Error of CAN-Receive-Frame
DM19Vol2; NOX sensor downstream
7-9-5
check of missing injector adjustment
value programming (IMA) injector 7 (in
firing order)
7-9-6
check of missing injector adjustment
value programming (IMA) injector 8 (in
firing order)
7-9-8
Injector cylinder bank 2 slave; short cir-
cuit
7-9-9
Injector powerstage output Slave defect
8-0-0
Injector 7 (in firing order); short circuit
8-0-0
High side to low side short circuit in the
injector 7 (in firing order)
8-0-0
Injector 7 (in firing order); interruption of
electric connection
8-0-1
Injector 8 (in firing order); short circuit
8-0-1
High side to low side short circuit in the
injector 8 (in firing order)
8-0-1
Injector 8 (in firing order); interruption of
electric connection
8-0-4
Too many recognized misfires in cylinder
7 (in firing order)
8-0-5
Too many recognized misfires in cylinder
8 (in firing order)
7-7-2
Zerofuel calibration injector 7 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 7 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 8 (in firing
order); maximum value exceeded
Short Text Detail
Fuel Balance Control integrator injector 7 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 7 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 8 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 8 (in fir-
ing order); minimum value exceeded
Timeout Error of CAN-Receive-Frame
DM19Vol1; NOX sensor upstream
Timeout Error of CAN-Receive-Frame
DM19Vol2; NOX sensor downstream
check of missing injector adjustment value pro-
gramming (IMA) injector 7 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 8 (in firing order)
Injector cylinder bank 2 slave; short circuit
Injector powerstage output Slave defect
Injector 7 (in firing order); short circuit
High side to low side short circuit in the injector
7 (in firing order)
Injector 7 (in firing order); interruption of electric
connection
Injector 8 (in firing order); short circuit
High side to low side short circuit in the injector
8 (in firing order)
Injector 8 (in firing order); interruption of electric
connection
Too many recognized misfires in cylinder 7 (in
firing order)
Too many recognized misfires in cylinder 8 (in
firing order)
Zerofuel calibration injector 7 (in firing order);
maximum value exceeded
Zerofuel calibration injector 7 (in firing order);
minimum value exceeded
Zerofuel calibration injector 8 (in firing order);
maximum value exceeded
D 23.18 105