SPN
FMI
97
110
4
98
110
0
99
110
0
101
111
1
109
523929
0
110
523930
0
111
523931
0
112
523932
0
113
523933
0
114
523934
0
115
523929
1
116
523930
1
117
523931
1
118
523932
1
119
523933
1
120
523934
1
121
1109
2
122
523698
11
D 23.18 48
Code
Error Identification
2-2-5
Sensor error coolant temperature; signal
range check low
2-3-2
Coolant temperature; system reaction
initiated
2-3-2
Coolant temperature; system reaction
initiated
2-3-5
Coolant level too low
7-2-4
Fuel Balance Control integrator injector 1
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 2
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 3
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 4
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 5
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 6
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 1
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 2
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 3
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 4
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 5
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 6
(in firing order); minimum value
exceeded
3-4-1
Engine shut off demand ignored
5-9-2
Shut off request from supervisory moni-
toring function
Short Text Detail
Sensor error coolant temperature; signal range
check low
High coolant temperature; warning threshold
exceeded
High coolant temperature; shut off threshold
exceeded
Coolant level too low
Fuel Balance Control integrator injector 1 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 2 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 3 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 4 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 5 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 6 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 1 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 2 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 3 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 4 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 5 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 6 (in fir-
ing order); minimum value exceeded
Engine shut off demand ignored
Shut off request from supervisory monitoring
function
Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido