Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 210

Terminadora de firmes
Tabla de contenido
KWP
SPN
FMI
518
523917
0
521
523917
1
524
523917
3
525
523917
4
526
523918
2
528
523918
0
531
523918
1
534
523918
3
535
523918
4
543
676
11
544
676
11
545
729
5
547
729
12
559
523895
13
560
523896
13
561
523897
13
562
523898
13
563
523899
13
564
523900
13
D 23.18 54
Code
Error Identification
7-1-8
Physical range check high for DV1 &
DV2 upstream pressure; shut off regen-
eration
7-1-8
Physical range check low for DV1 & DV2
upstream pressure; shut off regeneration
7-1-8
Sensor error DV1 & DV2 upstream pres-
sure; signal range check high
7-1-8
Sensor error DV1 & DV2 upstream pres-
sure; signal range check low
7-1-7
Sensor DV1 & DV2 upstream tempera-
ture; plausibility error
7-1-7
Physical range check high for DV1 &
DV2 upstream temperature; shut off
regeneration
7-1-7
Physical range check low for DV1 & DV2
upstream temperature; shut off regener-
ation
7-1-7
Sensor error DV1 & DV2 upstream tem-
perature; signal range check high
7-1-7
Sensor error DV1 & DV2 upstream tem-
perature; signal range check low
2-6-3
Cold start aid relay; open load, relay
error.
2-6-3
Cold start aid relay; open load, relay
error.
2-6-3
Cold start aid relay open load
2-6-3
Cold start aid relay; over temperature
error
7-0-6
Check of missing injector adjustment
value programming (IMA) injector 1 (in
firing order)
7-0-7
check of missing injector adjustment
value programming (IMA) injector 2 (in
firing order)
7-0-8
check of missing injector adjustment
value programming (IMA) injector 3 (in
firing order)
7-0-9
check of missing injector adjustment
value programming (IMA) injector 4 (in
firing order)
7-1-0
check of missing injector adjustment
value programming (IMA) injector 5 (in
firing order)
7-1-1
check of missing injector adjustment
value programming (IMA) injector 6 (in
firing order)
Short Text Detail
Physical range check high for DV1 & DV2
upstream pressure; shut off regeneration
Physical range check low for DV1 & DV2
upstream pressure; shut off regeneration
Sensor error DV1 & DV2 upstream pressure;
signal range check high
Sensor error DV1 & DV2 upstream pressure;
signal range check low
Sensor DV1 & DV2 upstream temperature;
plausibility error
Physical range check high for DV1 & DV2
upstream temperature; shut off regeneration
Physical range check low for DV1 & DV2
upstream temperature; shut off regeneration
Sensor error DV1 & DV2 upstream tempera-
ture; signal range check high
Sensor error DV1 & DV2 upstream tempera-
ture; signal range check low
Cold start aid relay error.
Cold start aid relay open load
Cold start aid relay open load
Cold start aid relay; over temperature error
Check of missing injector adjustment value pro-
gramming (IMA) injector 1 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 2 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 3 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 4 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 5 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 6 (in firing order)
Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido