Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 254

Terminadora de firmes
Tabla de contenido
KWP
SPN
FMI
562
13
563
13
564
13
836
3
837
4
834
5
835
12
1251
0
1252
0
1261
6
1249
7
1248
9
1250
12
55
14
58
0
60
3
61
3
62
4
1253
7
63
11
59
12
66
0
D 23.18 98
Code
Error Identification
7-0-9
check of missing injector adjustment
value programming (IMA) injector 4 (in
firing order)
7-1-0
check of missing injector adjustment
value programming (IMA) injector 5 (in
firing order)
7-1-1
check of missing injector adjustment
value programming (IMA) injector 6 (in
firing order)
7-6-1
Electrical fuel pre - supply pump; short
circuit to battery
7-6-1
Electrical fuel pre - supply pump; short
circuit to ground
7-6-1
Electrical fuel pre - supply pump; open
load
7-6-1
Electrical fuel pre - supply pump; power-
stage over temperature
6-9-5
Air Pump; internal error
6-9-5
Air Pump; internal error
6-9-5
Air Pump; over current
6-9-5
Air pump; CAN communication inter-
rupted no purge function available
6-9-5
Air Pump; CAN communication lost
6-9-5
Air Pump; internal error
6-9-5
Air pump doesn´t achieve air mass flow
setpoint
7-2-3
Burner dosing valve (DV2); overcurrent
at the end of the injection phase
7-2-3
Burner dosing valve (DV2); short circuit
to battery
7-2-3
Burner dosing valve (DV2); short circuit
to battery
7-2-3
Burner dosing valve (DV2); short circuit
to ground
8-5-0
Burner dosing valve (DV2); blocked
closed
7-2-3
Burner dosing valve (DV2); short circuit
high side powerstage
7-2-3
Burner dosing valve (DV2); powerstage
over temperature
7-2-2
Physical range check high for burner
dosing valve (DV2) downstream pres-
sure; shut off regeneration
Short Text Detail
check of missing injector adjustment value pro-
gramming (IMA) injector 4 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 5 (in firing order)
check of missing injector adjustment value pro-
gramming (IMA) injector 6 (in firing order)
Electrical fuel pre - supply pump; short circuit to
battery
Electrical fuel pre - supply pump; short circuit to
ground
Electrical fuel pre - supply pump; open load
Electrical fuel pre - supply pump; powerstage
over temperature
Air Pump; powerstage over temperature
Air Pump; operating voltage error
Air Pump; over current
Air pump; CAN communication interrupted no
purge function available
Air Pump; CAN communication lost
Air Pump; internal error
Air pump doesn´t achieve air mass flow set-
point
Burner dosing valve (DV2); overcurrent at the
end of the injection phase
Burner dosing valve (DV2); short circuit to bat-
tery
Burner dosing valve (DV2); short circuit to bat-
tery on high side
Burner dosing valve (DV2); short circuit to
ground
Burner dosing valve (DV2); blocked closed
Burner dosing valve (DV2); short circuit high
side powerstage
Burner dosing valve (DV2); powerstage over
temperature
Physical range check high for burner dosing
valve (DV2) downstream pressure; shut off
regeneration
Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido