KWP
SPN
FMI
1169
523951
1
1170
523612
12
1171
175
2
1173
523973
14
1174
523974
14
1175
523975
14
1176
523976
14
1177
523977
14
1178
523978
14
1180
168
0
1181
168
1
1182
172
0
1183
172
1
1187
523980
14
1192
523922
12
1193
1180
0
1194
1180
1
1216
523914
5
1217
523914
11
1219
524018
14
1220
524022
14
1221
524023
14
1222
190
14
D 23.18 68
Code
Error Identification
7-7-2
Zerofuel calibration injector 6 (in firing
order); minimum value exceeded
5-5-5
ECU reported internal software error
1-4-4
Oil temperature; plausibility error
7-7-9
SCR Tamper detection; derating timer
below limit 1
7-7-9
SCR Tamper detection; derating timer
below limit 2
7-8-0
Urea quality; derating timer below limit 1
7-8-0
Urea qulaity; derating timer below limit 2
7-8-1
Urea tank level; derating timer below limit
1
7-8-1
Urea tank level; derating timer below limit
2
3-1-8
Physikal range check high for battery
voltage
3-1-8
Physikal range check low for battery volt-
age
2-2-6
Physical range check high for intake air
temperature
2-2-6
Physical range check low for intake air
temperature
7-8-4
Bad quality of reduction agent detected
Over temperature error on burner shut of
valve
Exhaust gas temperature upstream tur-
bine; out of range, system reaction initi-
ated
Exhaust gas temperature upstream tur-
bine; out of range, system reaction initi-
ated
8-5-1
Glow plug control; open load
8-5-1
Glow plug control; internal error
7-8-6
DPF wasn´t regenerated, power reduc-
tion phase 1 (manuell regeneration
request)
7-8-6
DPF wasn´t regenerated, power reduc-
tion phase 2 (manuell regeneration
request)
7-8-6
DPF wasn´t regenerated, warning condi-
tion (manuell regeneration mode)
2-1-2
Speed detection; out of range, signal dis-
rupted
Short Text Detail
Zerofuel calibration injector 6 (in firing order);
minimum value exceeded
Internal software error ECU
Customer oiltemperature: signal unplausible
SCR Tamper detection; derating timer below
limit 1
SCR Tamper detection; derating timer below
limit 2
Urea quality; derating timer below limit 1
Urea qulaity; derating timer below limit 2
Urea tank level; derating timer below limit 1
Urea tank level; derating timer below limit 2
Physikal range check high for battery voltage
Physikal range check low for battery voltage
Physical range check high for intake air tem-
perature
Physical range check low for intake air temper-
ature
Bad quality of reduction agent detected
Over temperature error on burner shut of valve
Physical range check high for exhaust gas tem-
perature upstream turbine
Physical range check low for exhaust gas tem-
perature upstream turbine
Glow plug control release line; short circuit
error
Glow plug control; internal error
DPF wasn´t regenerated, power reduction
phase 1 (manuell regeneration request)
DPF wasn´t regenerated, power reduction
phase 2 (manuell regeneration request)
DPF wasn´t regenerated, warning condition
(manuell regeneration mode)
Camshaft- and Crankshaft speed sensor signal
not available on CAN