Descripciones de parámetros
9-23 Parameters for Signals
Matriz [1000]
Sólo lectura
Option:
[1672] Counter A
3
3
[1673] Counter B
[1674] Prec. Stop Counter
[1675] Analog In X30/11
[1676] Analog In X30/12
[1677] Analog Out X30/8 [mA]
[1678] Analog Out X45/1 [mA]
[1679] Analog Out X45/3 [mA]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1684] Comm. Option STW
[1685] FC Port CTW 1
[1686] FC Port REF 1
[1690] Alarm Word
[1691] Alarm Word 2
[1692] Warning Word
[1693] Warning Word 2
[1694] Ext. Status Word
[1860] Digital Input 2
[3310] Sync Factor Master
[3311] Sync Factor Slave
[3401] PCD 1 Write to MCO
[3402] PCD 2 Write to MCO
[3403] PCD 3 Write to MCO
[3404] PCD 4 Write to MCO
[3405] PCD 5 Write to MCO
[3406] PCD 6 Write to MCO
[3407] PCD 7 Write to MCO
[3408] PCD 8 Write to MCO
[3409] PCD 9 Write to MCO
[3410] PCD 10 Write to MCO
[3421] PCD 1 Read from MCO
[3422] PCD 2 Read from MCO
[3423] PCD 3 Read from MCO
[3424] PCD 4 Read from MCO
[3425] PCD 5 Read from MCO
[3426] PCD 6 Read from MCO
[3427] PCD 7 Read from MCO
[3428] PCD 8 Read from MCO
[3429] PCD 9 Read from MCO
[3430] PCD 10 Read from MCO
[3440] Digital Inputs
[3441] Digital Outputs
[3450] Actual Position
[3451] Commanded Position
[3452] Actual Master Position
[3453] Slave Index Position
[3454] Master Index Position
[3455] Curve Position
[3456] Track Error
122
Guía de programación del FC 300
Función:
[3457] Synchronizing Error
[3458] Actual Velocity
[3459] Actual Master Velocity
[3460] Synchronizing Status
[3461] Axis Status
[3462] Program Status
[3464] MCO 302 Status
[3465] MCO 302 Control
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2
[4280] Safe Option Status
[4285] Active Safe Func.
[4286] Safe Option Info
[0]
[1]
[0]
[1]
0
®
MG33MD05 - VLT
es una marca registrada de Danfoss.
9-23 Parameters for Signals
Matriz [1000]
Sólo lectura
Option:
9-27 Parameter Edit
Option:
Función:
Los parámetros se pueden editar mediante el
Profibus, la Interfaz estándar RS485 o el LCP.
Disabled Desactiva la edición mediante profibus.
Enabled Activa la edición mediante profibus.
*
9-28 Process Control
Option:
Función:
El control de proceso (ajuste de código de
control, referencia de velocidad y datos de
proceso) es posible mediante Profibus o
mediante el bus de campo estándar, pero no
simultáneamente. El control local siempre es
posible mediante el LCP. El control mediante
control de proceso es posible con cualquier
terminal o bus de campo dependiendo del
ajuste de 8-50 Coasting Select a 8-56 Preset
Reference Select.
Disable
Desactiva el control de proceso mediante el
Profibus y activa el control de proceso mediante
el fieldbus estándar o Profibus Maestro Clase 2.
Enable
Permite el control de proceso mediante el
*
cyclic
Profibus Maestro Clase 1 y desactiva el control
master
de proceso mediante fieldbus estándar o
Profibus Maestro Clase 2.
9-44 Fault Message Counter
Range:
Función:
[0 - 65535 ] Este parámetro muestra el número de eventos
*
de error guardados en los 9-45 Fault Code y
9-47 Fault Number. La capacidad máx. del
buffer es de ocho eventos de error. El buffer y
el mostrador se ajustan a 0 tras el reinicio o
arranque.
Función: