NOTES
Unpack the mirror. Check the box thoroughly for all hardware and loose parts. Carefully inspect the mirror for damage.
DANGER:
breaker or fuse box before attempting any installation procedure.
DANGER:
CAUTION:
grounded AC power outlet and a grounded AC electrical circuit. All wiring should be done by a qualified licensed electrician.
CAUTION:
unplugged from the power outlet before servicing.
IMPORTANT: Power for the defogger should be provided separately from the electricity to the lights so that the defogger can be
controlled independently of the lights and should be wired to a separate switch.
NOTE: Requires 120 VAC 20 amp GFCI circuit.
NOTE: Requires an approved compatible dimmer for installation (not included). Refer to the dimmer recommendation on page 2.
Observe all local electrical codes and building codes. Wire the mirror in accordance with the electrical codes.
This mirror is for indoor use only.
This mirror is UL listed for damp locations and conforms to UL 962; certified to CAN/CSA C22.2 Canadian Electrical Code, Part I.
This installation may require more than one person.
DISCONNECT POWER BEFORE INSTALLATION
Grounding instructions:
For a grounded, cord-connected product rated max 15 amperes and intended for use on a nominal 120-volt supply circuit:
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in sketch A (below).
Make sure that the product is connected to an outlet having the same configuration as the plug.
No adapter should be used with this product as illustrated in sketch B and C.
A
Grounded pin
© 2019 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
Installation instructions
Risk of personal injury. To avoid possible electrical shock, the electricity must be turned off at the circuit
Risk of personal injury. To avoid possible electrical shock, the mirror must be properly grounded.
Grounding instructions for connected products: Both power leads of this product must be connected to a
This mirror may be equipped with two power leads. Be certain that ALL power leads are disconnected/
DANGER - RISK OF SHOCK -
Grounded outlet
Grounded
outlet box
B
Adapter
Metal screw
Grounded
outlet box
3
C
Adapter
Tab for
grounding screw
Part no. 209-1308-rC rev. 08/29/19
Sculpt