Troubleshooting - Diamond DBT102/L Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

7.

TROUBLESHOOTING

The information shown below aims to help with
the identification and correction of any anomalies
and malfunctions which could occur during use.
Some of these problems can be resolved by the
Problem
The refrigerator unit does not start
The refrigerator unit functions
continuously, cooling insufficiently
Problem
The refrigerator unit does not stop
Presence of ice inside the
evaporator
Appliance noise
user. For the others, precise skill is required and
they must therefore only be carried out by
qualified staff.
Causes
No voltage
Other causes
Room too hot
Dirty condenser
Insufficient door sealing
Insufficient quantity of
refrigerant gas
Condenser fan at a standstill
Evaporator fan standstill
Causes
Probe faulty
Circuit board fault
Persistent vibrations
17
ENGLISH
Solutions
Check the power supply cable.
Check fuses.
Check the correct connection of the
appliance.
If the problem persists,
contact the after-sales centre.
Air the environment
clean the condenser
check the gaskets
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Solutions
Contact the after-sales
centre.
Contact the after-sales
centre.
Carry out a defrosting cycle possibly
with the door open.
If the problem persists,
contact the after-sales centre.
check there is no contact between
the appliance and other objects
inside or outside
GB
Tabla de contenido
loading

Este manual también es adecuado para:

Abv4042

Tabla de contenido