Product Application Limits; Installation And Connections; Installation Warnings - Nice MORX Instrucciones Y Advertencias De Instalación Y Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
– Transponder card reader system – in this system, automation is controlled by
transponder cards, which the user swipes closely over the reader: MORX receives the
card code, checks its validity (i.e. whether it is registered in its memory) and, if it is,
activates the output in question. • Depending on how a card is programmed, it may
activate only Output-1, only Output-2, or both. Note – the MORX memory may con-
tain many cards, each of which activates a different output.
CAUTION! – All uses other than the intended use described and use in en-
vironmental conditions other than those described in this manual should be
considered improper and forbidden!

3 - PRODUCT APPLICATION LIMITS

l CAUTION! – A single decoder may be connected to up to 4 keypads or, AL-
TERNATIVELY, 1 card reader. l The decision whether to connect it to keypads or a
reader must be made while its memory is still empty. l Before installing the unit, read
the "Technical specifications" chapter in this manual and those of any devices you in-
tend to connect to the decoder, to ensure that its installation conditions are within the
manufacturer's declared limits.

4 - INSTALLATION AND CONNECTIONS

4.1 - Installation warnings

l EDS / ETP must be installed onto a vertical wall. EDSI must be installed flush into a
vertical wall. These products are IP rated for outdoors installation.
l MORX has a protection rating of IP 30; it can thus be installed inside suitably pro-
tected control units or enclosures.
l The keypad/reader must be installed in a position which makes it easy for the user
to enter his codes or swipe his card. We recommend installing them around 1.5 m
off the ground.
l The installation location, surface and position must conform with the following
specifications: a) they must be compatible with the product's overall dimensions,
b) they must provide easy access to the product for use and maintenance, c) they
must protect the product against impact, d) the surface must be stable and robust
for a secure installation.
4.2 - Electrical installation warnings
l Before hooking up the product (par. 4.3) check the power supply and electrical
loads connected to the output relays.
l The MORX and EDS / EDSI / ETP must be hooked up with a two wire cable (the
polarity does not matter). For distances of less than 10 m, you can use a simple 2 x
0.5 mm
2
cable; for longer distances up to 30 m, use a shielded cable, and connect
the shield to earth only at the decoder end. Caution! – The system is not guaran-
teed to operate at distances of more than 30 m between the decoder and other
devices.
l EDS / EDSI only – If you install multiple keypads in a cascade pattern, use a single
cable and do not interrupt its shielding.
l MORX only – The decoder can be powered at either 12V or 24V, and with AC or DC.
l General note – The two wires used for connecting the system devices to each
other carry an encoded signal; this increases the security of the system since any
attempt to hook onto these wires from outside the system itself is totally ineffective.
4.3 - STEP BY STEP GUIDE to installation, hookup,
programming and final testing
01. EDS / EDSI keypads only: refer to Table 2 and select the number of keypads
you want to install (up to 4); you can see how this affects other aspects of the in-
stallation (number of keypads –> addressing –> programming method –> num-
ber of programmable combinations).
02. Refer to par. 4.1 to select the correct surface and position for the installation of
the various devices.
03. Refer par. 4.2 to identify the technical characteristics of the cable used to hook
up the various devices.
04. Lay the cable ducting.
05. Secure the back of each device (EDS / EDSI / ETP) to the wall: locate each de-
vice in the positioned identified in step 02, and mount them as described in their
instruction manuals. Caution! – Do not mount the electronic module yet; it must
be programmed and the system tests completed before it is definitively installed.
06. The MORX decoder has two outputs controlled by NO relay contacts. If you
wish to use an NC contact, proceed as shown in fig. 1 (cut point "A" and sol-
der point "B").
07. If you wish to double the memory capacity of the MORX's memory, refer to fig. 2.
Caution! – Do not swap the two BM cards around.
08. Mount the MORX inside a suitably protected control unit or control enclosure.
Caution! – It is not rated for installation outdoors.
09. CAUTION! – All electrical connections must be made without electri-
cal power; route the cables through the ducting and hook the devices up as
shown in their instructions and in fig. 3 of this manual: no particular polarity
need be observed.
English – 2
Tabla de contenido
loading

Tabla de contenido