Nice MORX Instrucciones Y Advertencias De Instalación Y Uso página 17

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
05. After 2 seconds, the reader beeps 1 time and enables the units.
06. Now swipe the card in question one time for each single time you want the card
to be used.
(*) – You must use MASTER-1, MASTER-2 of the SINGLE-MASTER, depending on
the output (1, 2, or both) to which the card in question is mapped.
7.B.11
Professional
To program (with a MASTER...) an output (1, 2 or both)
in TIMER mode
This procedure assigns a set activation period (from 0.5 to 6500 seconds) to the out-
put mapped to the MASTER being used to program it. As a result, when the output is
activated, it remains active for a set time.
01. Swipe the MASTER(*) over the reader 6 times.
02. Move the MASTER up to the reader again and hold it there.
03. Wait for the reader to beep 3 times (the time starts from the third beep)...
04. ...now let the time you want to program time out (from 0.5" to 1h 50'. Note –
the output is active during this time) and then move the MASTER away from
the reader.
(*) – To program output-1 use MASTER-1; to program output-2 use MASTER-2; and
program both outputs together, use the SINGLE-MASTER.
Note – To restore the output to momentary mode, repeat the procedure up to step
03, and move the MASTER away from the reader during its third beep (thus setting an
activation time of 0 seconds).
7.B.12
Professional
To program (with a MASTER...) an output (1, 2 or both)
in BISTABLE mode
BISTABLE mode transforms the output (selected with the appropriate MASTER card)
into an on/off switch: the output activates the first time the card is swiped and deac-
tivates the second time it is swiped.
01. Swipe the MASTER(*) over the reader 6 times.
02. Move the MASTER up to the reader again and hold it there.
03. Wait for the reader to beep 1 time and immediately move the MASTER away
from the reader.
(*) – To program output-1 use MASTER-1; to program output-2 use MASTER-2; and
program both outputs together, use the SINGLE-MASTER.
Note – To restore the output to momentary mode, repeat procedure 7.B.11 up
to step 03, and move the MASTER away from the reader during its third beep (thus
setting an activation time of 0 seconds).
7.B.13
Professional
To program (with a MASTER...) outputs 1 and 2 in
SECURITY mode
This function sets output-1 and output-2 to operate in SECURITY mode: output-1
is set to BISTABLE mode to arm/disarm a security system, while output-2 outputs a
pulse when the system is armed and two pulses when it is disarmed.
01. Swipe any MASTER card over the reader 6 times.
02. Move the MASTER up to the reader again and hold it there.
03. Wait for the reader to beep 2 times and, immediately move the MASTER
away from the reader.
Note – To restore the output to momentary mode, repeat procedure 7.B.11 up to
step 03, and move the MASTER away from the reader during its third beep (thus set-
ting an activation time of 0 seconds).
7.B.14
Professional
To program a new card with a previously
programmed card
This procedure does not require a MASTER card. • To run this procedure, you
need an old (previously programmed) card, from which the new card will take its set-
tings (output-1, output-2, or both (1 and 2).
01. Hold the new card up to the reader for at least 5 seconds. Move the card away
from the reader.
02. Now swipe the old (previously programmed) card over the reader 3 times.
03. Hold the new card up to the reader 1 more time.
To save another card, repeat the procedure from the beginning.
7.B.15
Professional
To cancel the entire memory using any MASTER
This procedure completely cancels the decoder's BM memory, including the MAS-
TER cards themselves.
01. Swipe any MASTER card over the reader 5 times.
02. Wait for the read to beep 3 times.
03. Immediately after the third beep, hold the MASTER up to the reader and hold
it there.
04. Wait for the read to beep 5 times.
English – 16
Tabla de contenido
loading

Tabla de contenido