Activate Video Trigger; Activate External Trigger - Promax AE-966 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER'S MANUAL AE-966 / 967

6.2.10.2 Activate video trigger

Panel
1.- Press the Trigger key.
operation
2.- Press F2 (Trigger Condition). Select
Video.
3.- The video trigger icon appears at the
bottom of the display.
4.- Enter the trigger level (amplitude) using
the numerical keys. The value appears in the
command window.
5.- Press F5 (Trigger Freq) to set the
frequency
condition
6.- Enter the trigger frequency using the
numerical keys.
7.- To de-activate triggering, press F1 (Free
Run).
Trigger
dBm
level range
dBmV
dBμV
Trigger
0 ~ 3.0GHz
frequency
range

6.2.10.3 Activate external trigger

Panel
1.- Press the Trigger key.
operation
2.- Press F2 (Trigger Condition). Select Ext.
3.- The Ext. trigger icon appears at the bottom
of the display.
4.- Connect the external trigger signal to the
rear
panel
between 0V and 5V triggers.
04/2016
at
which
checks
the
-130 ~ +20dBm
-83.01 ~ +66.99dBmV
-23.01 ~ +126.99dBμV
terminal.
The
positive
Trigger
Trigger
Condition
F 2
Video Ext.
μ
Video: -20dBm
Trigger Freq
1.5GHz
trigger
μ
Free Run
Trigger
Trigger
Condition
F 2
Video Ext.
edge
F 5
F 1
Page 101

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ae-967

Tabla de contenido