Promax AE-966 Manual De Instrucciones página 238

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER'S MANUAL AE-966 / 967
3c. Delete
1.- Move the cursor to the target
correction
using the Arrow key.
point
2.- Press F2 (Delete). The
frequency and gain are
deleted together.
3.- To undo the last deletion, press
F4 (Undelete).
Example: point 3 deleted.
Pt.
1
2
3
4
5
4. Save
1.- Press F5 (Save Now). The
correction
edited data is saved internally.
set
2.- Press F6 (Return) to go back to
the previous menu.
5. Activate
1.- Press F2 (Correction On) to
correction
turn On the correction.
2.- The amplitude icon appears at
the bottom of the display.
After
Frequency response becomes linear (original), and the gain is
correction
compensated by +2 ~ +3dB.
04/2016
Freq. (MHz)
Gain
2200
2.5
2300
1.3
2400
2.8
2500
1.8
2600
1.2
Delete
F 2
Undelete
F 4
Pt.
Freq. (MHz)
1
2200
2
2300
3
2500
4
2600
5
Save Now
F 5
Return
F 6
Correction
F 2
On
Off
Gain
2.5
1.3
1.8
1.2