Example: after
Start frequency: 97.5MHz
Autoset
Span: 5MHz
Center frequency: 100MHz
6.2.3.2

RBW/VBW/Sweep Setting after Autoset

All the three BW related parameters, RBW, VBW, and Sweep, will be reset to
Auto mode when using Autoset, regardless of their previous settings
Limit vertical search range
Background You can set the amplitude floor so that the signals lower than the
setting will be ignored from Autoset search.
Panel
1.- Press the Autoset key.
operation
2.- Press F2 (Amp. Floor) to switch the range
from Auto (whole range) to manual
(limited range).
3.- Enter the amplitude in dB, using the
numerical keys. The Command window
shows the setting.
Range
dBm -80 ~ +20dBm, 0.1dB resolution.
dBmV -33.01 ~ +66.99dBmV, 0.01dB resolution.
dBμV +26.99 ~ +126.99dBμV, 0.01dB resolution.
Page 52
USER'S MANUAL AE-966 / 967
Stop frequency: 102.5MHz
Signal peak: 100MHz
Reference level: -30dBm
Autoset
Amp.Floor
Auto Man
μ
Amp. : -30dBm
F 2
04/2016