Other functions available
- Automatic closing. The automatic
closing timer is automatically activated
at the end of the opening cycle. The
preset, adjustable automatic closing
time is automatically interrupted by the
activation of any safety system, and is
deactivated after a STOP command or
in case of power failure;
- Obstacle presence detection: When
the motor is stopped (gate is closed,
open or half-open after an emergency
stop command), the transmitter and
the control pushbutton will be
deactivated if an obstacle is detected
by one of the safety devices (for
example, the photocells);
- Hammer movement. At every opening
command, the wings press the closing
stop-ledge for a second, thus facilitat-
ing the release operation of the electric
lock connected to terminals 11-S.
It is only active if the wings are closed
and at the end of the work time or at
st
the 1
manoeuvre after the system has
been powered;
- Enabling functions of partial stop or
re-closure during opening, normally-
closed contact (2-CX), select one of
the two functions by setting Dip (see
page 14);
- "Operator present" function: Gate
operates only when the pushbutton is
held down (the radio remote control
system is deactivated);
- Partial opening , second motor door
opening, adjusted with TR2M trimmer;
it is activated by collecting to the
terminals 2-3P;
- Pre-flashing for 5 seconds, while the
door is opening and closing;
- Type of command:
-open-stop-close-stop for pushbutton
and radio transmitter;
- open-close-reverse for pushbutton
and radio transmitter;
-open only for radio transmitter.
Adjustments
- Automatic closure time;
- Partial opening time and delay in
closing of the M2 motor;
- Operating time.
Important! Disconnect the unit
from the main power lines before
carrying out any operation inside the
unit.
-5-