2. TECHNICAL DATA
PPB2
Automation type: LIGHT
(for internal use, not exposed to wind
pressure)
Dimensions: 82 x 117 x 443 mm
(Height x Depth x Length)
200 kg x 0,8 m
Opening and closing time: 2 – 6 s
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Power supply: 100–240 Vca 50/60 Hz
Rated power: 40 W
Stand-by: 8 W
Rated load: 20 Nm
Protection rating: IP 20
Operating temperature:
-15 °C
+50 °C
Parameter Settings:
Buttons and Display
Connections to control and safety
devices:
Dedicated connecting terminals
Power output for accessories:
12 Vdc (1 A max)
Memory for settings and saving:
Micro SD standard
Function selector device with
transponder key: 001PBBA04
Battery power device for emergency
opening: 001PBBA03
N.B. The technical data above refer to average conditions of use and cannot be certain in each case. Each automatic entrance
variables such as: friction, balancing and environmental conditions that may substantially change both the duration and the
quality of the operation of the automatic or some of its components, including the automation. The installer must to adopt
adequate safety coefficients for each particular installation.
FA00008-EN v.7 – 05/2017
PBBS2
Automation type: SPRING
(with closing
spring)
Dimensions: 135 x 118 x 503 mm
(Height x Depth x Length)
220 kg x 0,8 m
Opening and closing time: 2 – 6 s
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Power supply: 100–240 Vca 50/60 Hz
Rated power: 70 W
Stand-by: 8 W
Rated load: 23 Nm
Protection rating: IP 20
Operating temperature:
-15 °C
+50 °C
Parameter Settings:
Buttons and Display
Connections to control and safety
devices:
Dedicated connecting terminals
Power output for accessories:
12 Vdc (1 A max)
Memory for settings and saving:
Micro SD standard
Function selector device with
transponder key: 001PBBA04
Battery power device for emergency
opening: 001PBBA05
4
PBB3
Automation type: HEAVY
Dimensions: 104 x 118 x 463 mm
(Height x Depth x Length)
300 kg x 0,8 m
Opening and closing time: 2 – 6 s
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Power supply: 100–240 Vca 50/60 Hz
Rated power: 70 W
Stand-by: 8 W
Rated load: 40 Nm
Protection rating: IP 20
Operating temperature:
-15 °C
+50 °C
Parameter Settings:
Buttons and Display
Connections to control and safety
devices:
Dedicated connecting terminals
Power output for accessories:
12 Vdc (1 A max)
Memory for settings and saving:
Micro SD standard
Function selector device with
transponder key: 001PBBA04
Battery power device for emergency
opening: 001PBBA05