CAME FLUO-SW Manual De Ensamblado E Instalación página 66

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

10. ADJUSTMENT OF THE KINETIC ENERGY OF THE DOOR
To reduce the kinetic energy of the door make the following adjustments: - adjust the force PUSH ≤ 5;
- adjust the opening speed (VOP) so as to open the door (from 0° to 80°) at the times indicated in the table;
- adjust the closing speed (VCL) so as to close the door (from 90° to 10°) at the times indicated in the table.
Door width
0,75 m
0,85 m
1,00 m
1,20 m
11. TROUBLESHOOTING
In addition to the following list of possible problems, there are warnings provided by the display, as described in chapter 7.5.
Problem
The automation does not
open or close.
The automation does not
perform the functions set.
The movement of the doors
isn't linear, or reverse the
movement for no reason.
The automation opens but
does not close
Safety devices not activating.
The automation opens by
itself.
FA00008-EN v.7 – 05/2017
50 kg
60 kg
3,0 s
3,0 s
3,0 s
3,0 s
3,5 s
3,5 s
4,0 s
4,5 s
Possible causes
No power supply (display off).
Short circuited external accessories.
The door is locked by bolts and locks.
Function selector incorrectly set.
Control devices or safety always
activated.
The automation does not successfully
perform the automatic learning.
Anomalies during the safety devices
test.
The opening devices are activated.
The automatic closing doesn't work.
Incorrect connections between the
safety devices and electronic control.
The opening and safety devices are
unstable or detect moving bodies
Door weight
70 kg
3,0 s
3,5 s
4,0 s
4,5 s
Remedy
Check the power supply.
Disconnect all accessories from terminals 0-1
and reconnect them one at a time (check for
voltage 12V).
Check the freely move of the doors
Check and correct the settings of the function
selector.
Disconnect devices from the terminal and verify
the operation of the door.
Perform a reset using the command 1-29 , or
power off and power on the automation.
Jumper contacts one at a time 41 -6A , 41 - 8A.
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving objects in the field of
action.
Check the settings of the function selector .
Check that the safety contacts of the devices
are properly connected to the terminal blocks
and the relative jumpers have been removed.
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving bodies in the field of
action.
32
80 kg
90 kg
3,0 s
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
5,0 s
5,5 s
CAME S.p.A.
Tabla de contenido
loading

Tabla de contenido