MR8534/MR8570/MR8590
Safety sensor for automatic swing doors
Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
DESCRIPTION
1
2
3
4
5
6
TECHNICAL SPECIFICATIONS
Technology:
Emission fi eld:
Mounting height:
Reaction time:
Max. presence time:
Supply voltage:
Max current consumption:
Output:
Max. contact voltage
Max. contact current
Max. switching power
Input:
Max. contact voltage:
Voltage threshold:
Max. number of modules:
Refl ectivity:
Degree of protection:
Temperature range:
Expected lifetime:
Norm conformity:
* max. mounting height for BS 7036-conformity (UK): 3.25 m
1.
profi le
2.
supporting clip
3.
main connector
4.
DIP-switch
5.
calibration screw
6.
receiver
active infrared with background suppression
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
1.3 m to 3.5 m
64 ms (typ)
infi nite
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
95 mA @ 24 V AC/ 70 mA @ 24 V DC; 170 mA @ 12 V AC/ 130 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
2 relays (free of potential contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
1 optocoupler (free of potential contact)
30 V
high: >10 V DC; low: <1 V DC
4 (up to 6 if 24 V DC)
min. 5% at IR-wavelength of 850 nm
IP53
-25 °C to +55 °C; 0-95% relative humidity, non condensing
20 years
EMC 2004/108/EC; MD 2006/42/EC; ROHS 2 2011/65/EU
DIN 18650-1:2012 ch. 5.7.4; BS 7036-2:1996*; EN 16005:2012 ch. 4.6.8;
EN 12978:2003 + A1:2009; EN 61508:2010; IEC 61496-2:2006; BGR 232;
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
7.
end cap
8.
clip with angle adjustment screw
9.
transmitter (TX)
10.
push button
11.
front face
Specifi cations are subject to changes without prior notice.
All values measured in specifi c conditions.
7
8
9
10
11