Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

8.2 MEMORY MANAGEMENT MENU
Using the buttons ↑ and ↓ select MEM, press ENTER to select and adjust the following memory management menu.
Display
Description
FSET
Restore all settings to factory defaults. Choose between the following values:
FACTORY
NO = no restore.
SETTINGS
YES = restore to factory settings.
FW
Programming procedure of electronic control.
FIRMWARE
Insert the micro SD memory in the electronic control.
UPGRADE
From this menu, choose the firmware version you want (from 0200 to - - - -).
Press ENTER until it starts the programming procedure that lasts about 30 seconds (the display
shows "WAIT • • • •"), at the end the display shows "SAVE".
After the procedure, remove the micro SD memory from the electronic control and store it for
future use.
Note: in the case of programming error or missing firmware (W100), proceed as follows:
the
power supply, insert the micro SD memory, give power supply, the programming procedure
starts automatically.
SIN
You can upload the menu settings used in another automation, already stored in the micro SD
SETTING
memory.
INPUT
Choose between the following values:
NO = no upload
YES = upload the menu settings from the micro SD memory
SOUT
You can save the menu settings of automation in use, in the micro SD memory. Choose between
SETTING
the following values:
OUTPUT
NO = no save
YES = save the menu settings of automation in the micro SD memory
8.3 ADVANCED PARAMETERS MENU
Using the buttons ↑ and ↓ select ADV, press ENTER to select and adjust the following advanced parameters.
Display
Description
8AEX
Exclusion of the operation of the sensor closing safety. Choose between the minimum and maximum
8A-
values:
EXCLUSION
minimum value = 0%
maximum value = 50%
6AEX
Exclusion of the operation of the sensor opening safety. Choose between the minimum and
6A-
maximum values:
EXCLUSION
minimum value = 0%
maximum value = 50%
ST6A
Operation of 6A safety command, after the door stop. Choose between the following values:
6A-SETTING
CLOS = automatic closing of the door
OPEN = continues the opening of the door
ELLK
Selecting the electric lock. Choose between the following values:
LOCK
NO = electric lock not connected
OPERATION
LOCK = standard electric lock (security operation)
TYPE
SAFE = anti-panic electric lock (safety operation)
AUTO = anti-panic electric lock (operation matched to the function selector)
LKPW
Power supply electric lock. Choose between the following values:
LOCK POWER
12 = 12V electric lock
SUPPLY
24 = 24V electric lock
FA00008-EN v.7 – 05/2017
24
Factory settings
NO
- - - -
disconnect
NO
NO
Factory settings
0
0
CLOS
NO
12
CAME S.p.A.
Tabla de contenido
loading

Tabla de contenido