7. Connect the keypad cable to new connection point on IND560x-PAB. This new connection
8. Additional connections must be made between the J3 terminal of the IND560x-PAB and the J4
3-24
METTLER TOLEDO IND560x Installation Manual
point is indicated with "KEYPAD" (Figure 3-29).
Figure 3-29: Keyboard Connection on IND560x-PAB
& J5 terminals of the IND560x main board (Figure 3-30). Table 3-8 indicates color codes for
wiring the connection. Install the connector included with the IND560x-PAB kit according to
these wiring codes.
Figure 3-30: IND560x-PAB (J3) to IND560x (J4/J5) Connection
Table 3-8: IND560x-PAB (J3) to IND560x (J4/J5) Wiring Color Code
IND560x-PAB
J3-1
J3-2
J3-3
J3-4
J3-6
J3-7
J3-9
The IND560x-PAB functions as a voltage splitter for the IND560x terminal. A single source
voltage comes into the IND560x-PAB from the NiMH battery pack. The IND560x-PAB splits this
single source voltage into the various voltages required by the IND560x terminal for its
IND560x Main Board
Wire Color
J5-1
J5-2
J5-3
J5-4
J4-6
J4-7
J4-9
Brown
Red
Orange
Yellow
Green
Blue
Black
64061929
|
11
|