To set the LOCK time: This function needs to be carried out at the time of day when you wish the unit to CLOSE and remain LOCKED.
Enter the Extended Modes by pushing the Red and Green buttons simultaneously for more than 2 seconds, then press the red button once (the unit will beep
twice) then again (the unit will beep three times) then again (the unit will beep four times) then again (the unit will beep five times) then once again (the unit will
beep six times) then once again and the unit will beep 7 times and you have arrived at Timer Mode. To enter Timer Mode, press both Red and Green buttons
simultaneously, the green light will stay illuminated and the red light will flash.
Pressing and releasing the Red button quickly will set the LOCK time. On releasing the Red Button the Petporte smart flap
of operation.
You must now activate Night Mode so that the unit recognizes the UNLOCK and LOCK times that you have programmed. To activate
Night Mode, press the Red button for less than 2 seconds.
Note:
1. The Timer Mode will only function when the unit is powered through the external power supply included with this unit. The Timer Mode is not available
when the unit enters battery backup mode.
2. In the event of a power cut, you will need to reset the unlock and lock times.
3. The Timer Mode supersedes the light level detector. The unit will no longer read the ambient light levels to decide if the unit should be locked or unlocked.
LED Indicator - Quick Guide
Explanation of LED Indicators:
Flash
Off
Off (Day) / On (Night)
Off
Flash
On
Battery Backup Facility
Your Petporte smart flap
has the facility to fit a backup battery, ensuring your cat can still have access to your house in the event of a mains power cut on the
®
low voltage power supply. When the Petporte smart flap
pressed against the flap, thus getting the battery out of sleep-mode.
To install batteries, remove the small cover plate with a screw driver and attach a 9-volt (IEC 6LR61) battery to the connecting snaps. Push battery into the
battery compartment and snap the small cover plate back in place.
Please note that the following functions are currently unavailable with your Petporte smart flap
1. Wall Mounting - Currently the Petporte smart flap
2. Night Mode - Currently Night Mode is unavailable when the unit enters battery backup mode.
3. Programming – When programming your cat into the Petporte smart flap
18
Flash
Off
On
Flash
Off
Flash
is operating under battery-mode ONLY, it will scan for the cat's microchip only AFTER the cat has
®
Battery Backup Facility is unable to function on a wall fitted unit.
®
®
, please connect the Cat Flap to mains power.
www.petsafe.net
Function
Power on but nothing programmed
Normal Operating Mode
Night Mode (Timer Mode)
Vet Mode
Open Mode
Battery Level Low
, when the unit is being operated by battery alone:
®
will return to its normal mode
®