TECHNICAL DATA

SOLM1020-BV
INPUT VOLTAGE
FREQUENCY
PHASES
EFFICIENCY
CURRENT RANGE @ 110 V
CURRENT RANGE @ 220 V
WELDING CURRENT @ 110 V
WELDING CURRENT @ 220 V
PROTECTION CLASS
POWER FACTOR COS ɸ
WORK CYCLE
WEIGHT
Earth clamp
Electrical
connection
(110 / 220) V ~
60 Hz
1 ~
ɳ 85%
...
MIG: (30 - 100) A
...
MMA: (20 - 85) A
...
MIG: (30 - 200) A
...
MMA: (20 - 170) A
...
MIG: (30 - 100) A
...
MMA: (20 - 85) A
...
MIG: (30 - 200) A
...
MMA: (20 - 170) A
IP21S
0,7
35 %
22 kg (48,5 lb)
E N G L I S H •

OPERATION INSTRUCTIONS

PREPARING YOUR WORK AREA
1. You must have a sturdy work table that is
open below the area you are welding. Molten
slag will be blown through the work metal, and
must be able to fall away freely
2. Your work table must allow the work metal
to be firmly clamped to prevent it accidentally
falling or moving.
3. The floor and surrounding area of your work
site must not be flammable. A clean cement
floor is recommended. The welding process will
eject molten metal slag onto the floor, and it
will scatter for 8-10 feet or more in any direc-
tion. Have an adequate fire extinguisher avail-
able if needed.
ASSEMBLY
ATTACH AIR SUPPLY
CAUTION: Do not use an Argon/Mixed pres-
sure regulator/flow meter with CO
gas. To use CO
Shielding gas, you must install
2
a CO
Shielding gas pressure regulator/flow
2
meter.
1. Make sure the Flow Adjust on the Pressure
Regulator/Flow Meter is turned off. Then Pres-
sure Regulator/Flow Meter (not included) firmly
onto the cylinder valve.
2. Connect the gas air inlet (1) to your supply
CO
Gas supply by one air hose (not supplied).
2,
And remember to fasten it with coupling.
3. Adjust the flow rate of the gas by turning the
Flow Adjust. The typical flow rate is 10-30 CFH
(cubic feet per hour). Make sure to check the
Welding Wire manufacturer's recommended
flow rate.
SETTING THE GUN POLARITY FOR WIRE TYPE
1. Set for Electrode Positive (GAS) for gas weld-
ing with solid-core wire and the gas supply is
needed.
NOTE: When it is gas welding, you also should
set common Wire feed rolls.
2. Set for Electrode Negative (DCEN) for gasless
flux core wire and this kind connect don't need
gas supply.
NOTE: When it is gas-less welding, you also
should set the special Wire feed rolls.
With no
tooth
on the
groove