Technical Data - Urrea SOLI9200-BV Manual De Usuario

Soldadora de arco inverter de cd
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

tact our company for the technical back-up or
service when they feel unable to work out the
technical hitch or problems.
THE MAINTENANCE INCLUDES
Dust removal. The service man must regularly
clean up the dust from the welder by the dry
compressed air (air compressor or the similar
device). Meanwhile examination can also be
performed to make sure there are no loose
parts and components inside the machine. Im-
mediate cleaning is needed if there is an accu-
mulation of dust. Under normal circumstance
cleaning is only required once a year unless
there is too much dust inside the welder. If so,
cleaning needs to be done every quarter of the
year.
Keep the welder cable plug in good condition.
The Welder Cable Plug needs to be checked
from time to time. In its regular usage, at least
it has to be inspected each month. However, it
is necessary to check it every time when it is in
the mobile circumstance.
WARNING: If the main loop voltage happens
to be a bit higher, safety precaution should be
taken before repair to avoid accidental shock.
The untrained people are forbidden to open
the case. Power source needs to be cut off be-
fore dust removal. Never tamper with wire or
damage the component parts when cleaning.
E N G L I S H •

TECHNICAL DATA

PHASES
INPUT VOLTAGE
FREQUENCY
EFFICIENCY
CURRENT RANGE
WELDING CURRENT (60%)
PROTECTION CLASS
POWER FACTOR COS ɸ
WEIGHT
U se r's m a n ua l
1 ~
120 V / 220 V ~
60 Hz
ɳ 80%
...
(20 - 200) A
...
(160 - 180) A
IP21S
0,93
9 kg (19,8 lb)
11

Hide quick links:

Tabla de contenido
loading

Tabla de contenido