Installation Clearances

30" (762mm) min. from bottom
of Overhead Hood to cooking
surface. 36" (914mm) min. If
hood contains combustible
materials
18" (457mm)
minimum
*35
" (911mm) Min. range height
with leveling legs fully retracted.
*36 ¾" (933mm) Max range height
with leveling legs fully extended.
Do not install the range such that the oven door is flush
with the cabinet face. A flush installation could result in
damage to the cabinets due to exposure to high heat.
For 36" Ranges {36" (914mm) or 42" (1067mm) Wide Hood
{42" (1067mm) or 48" (1219mm) for Island
For 48" Ranges {48" (1219mm) 54" (1372mm), or 60" (1524mm) Wide Hood
{54" (1372mm) for Island
36" Range - 36" (914mm)
48" Range - 48" (1219mm)
Min. distance between overhead cabinets
of combustible material
36" (914mm) or 48" (1219mm)
For Electrical & Gas Supply zones,
see Figure 3. Zone sizes & positions differ
Gas
Zone
CAUTION:
13" (330mm)
Max Cabinet
Depth
Range width
according to model.
Electrical
Zone
as defined in the "National Fuel Gas Code" (ANSI Z223.1, Current
Edition). Clearances from non-combustible materials are not part of the ANSI
Z21.1 scope and are not certified by CSA. Clearances of less than 12" (305
mm) must be approved by the local codes and/or by the local authority
having jurisdiction.
*The range height is adjustable. The level of the range top must be at the
same level or above the counter top level.
5" (127mm)
min to
combustible
sidewall
material
(both sides)
Cooking
Surface
F
1: C
IGURE
ABINET
CAUTION!
See Figure 2
36" (914mm) Min.
to combustible
material
from Cooking
Surface
C
LEARANCES
English 5